FireDOC Search

Author
Fattal, S. G.
Title
Guide for Safety Inspection of Jumpform and Slipform Systems Used in Concrete Cooling Tower and Chimney Construction.
Coporate
National Bureau of Standards, Washington, DC
Sponsor
Occupational Safety and Health Administration, Washington, DC
Report
NBSIR 83-2627
September 1983
Distribution
Available from National Technical Information Service
Keywords
cooling towers; chimneys; concrete construction; slip forms; structural members; construction joints; scaffolds; safety; inspection; guidelines
Identifiers
jump forms
Abstract
This report provides a basic guide for the safety inspection of jump form and slip form systems used in the construction of cooling towers and chimneys. The systems are described in terms of their components and operating procedures involved in the casting cycle of a typical lift. Special emphasis is given to the structural aspects of components which are most critical in the maintenance of overall structural integrity of the system during construction.