FireDOC Search

Author
Nakaya, I. | Tanaka, T. | Yoshida, M.
Title
Measurement of Doorway Flow Induced by Propane Fire.
Coporate
Building Research Inst., Tokyo, Japan
Report
NBSIR 85-3118,
Distribution
Available from National Technical Information Service
Book or Conf
National Bureau of Standards. 7th Joint Panel Meeting of the UJNR Panel on Fire Research and Safety. October 24-28, 1983, Gaithersburg, MD, 565-584 p., ['1983', '1985']
Keywords
propane
Abstract
It will be one of the most important subject to measure exact mass flow rate (inflow and outflow) through an opening for analyzing various aspects of fire. In strict way, this rate can be obtained by measuring the local gas velocities whole over the opening and integrating them. But this is too complex and tedious in most cases. When gas temperature in a room is nearly uniform like in the fully developed fire, it was shown by Kawagoe and Thomas that an opening mass flow rate can be easily calculated applying Bernoulli's relation.