FireDOC Search

Author
Stroup, D. W. | DeLauter, L. A. | Lee, J. H. | Roadarmel, G. L.
Title
Scotch Pine Christmas Tree Fire Tests. Report of Test. FR 4010.
Coporate
National Institute of Standards and Technology, Gaithersburg, MD
Report
Report of Test 4010; FR 4010, December 1, 1999, 36 p.
Keywords
fire tests | fire data | fire models | heat release rate | radiation heat flux
Abstract
A series of fire tests were conducted to characterize the potential hazard from ignition of Scotch Pine Christmas trees. Heat release rate was measured as a function of time from ignition using a large calorimeter. In addition, radiative flux and total heat flux were measured at a location 2m from the tree centerline. Seven of the trees were allowed to dry for approximately three weeks. These trees burned easily when ignited with an electric match. An eighth tree, freshly cut and kept in water until just before testing, could not be ignited.