FireDOC Search

Author
Sharp, G.
Title
Earthquake Damage to Passive Fire Protection Systems in Tall Buildings and Its Impact on Fire Safety.
Coporate
University of Canterbury, Christchurch, New Zealand
Report
Fire Engineering Research Report 03/8, October 2003, 104 p.
Distribution
FOR MORE INFORMATION CONTACT: School of Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand. Telephone: 643-364-2250, Fax: 643-364-2758, Website: http://www.civil.canterbury.ac.nz
Keywords
earthquakes | damage | high rise buildings | fire protection | fire safety | case histories | deformation | compatibility | risk analysis | emergencies | response time | fire resistance ratings | compartment fires | escape means | fire severity
Identifiers
Wellington Case Study; BRANZ Deformation Report (literature review); modified Mercalli earthquake intensity scale; visual basic for applications code, data retrieval macro; SIMULEX model of building 1, output file; simulation and analysis spreadsheets
Abstract
New Zealand is a country which is extremely prone to seismic activity. One of the many impacts an earthquake may have is to cause fires. If a fire was to start in a damaged multi-storey structure the safety of the occupants would undoubtedly be in question. During an earthquake large lateral forces are experienced by tall buildings, this in turn causes defomlations to take place. It is these defomlations that can cause damage to various parts of the structure. One very important component of any structure is its passive fire protection; unfortunately passive protection systems such as Gypsum plasterboard walls are very vulnerable to earthquake damage. Discovering the extent to which this reduces the fire safety of buildings is the primary objective of this project. Currently in New Zealand there are no legislative design criteria for the event of fire following an earthquake. Another aim of this research is to gain a further understanding of this gap between the design of tall buildings for the demands of earthquake and the demands of fife. A greater understanding of the risks posed by post-earthquake fife is to be gained by addressing the vulnerability of tall buildings. To detemline the level of risk associated with post-earthquake fire the topic was split into two parts. The fIrst part involved developing models to calculate a factor of safety for burning buildings as a ratio of available and actual escape times. The second part looked at how damage to plasterboard walls, protecting escape paths, would affect the fIre safety of the building. By considering the results of these two parts an overall assessment of the risk associated with post-earthquake fire was made. It was found that for fire following an earthquake in buildings greater than ten stories, in which the sprinklers do not operate; the occupants may be unsafe because the expected escape time is greater than the expected failure time of the fire rated walls surrounding the escape route.