Fang, J. B.
- Title
- Fire Performance of Selected Residential Floor Constructions Under Room Burnout Conditions. Interim Report.
- Coporate
- National Bureau of Standards, Gaithersburg, MD
- Sponsor
- Department of Housing and Urban Development, Washington, DC
- Report
-
NBSIR 80-2134
December 1980
79 p.
- Distribution
- AVAILABLE FROM: National Technical Information Service (NTIS), Technology Administration, U.S. Department of Commerce, Springfield, VA 22161. Telephone: 1-800-553-6847 or 703-605-6000; Fax: 703-605-6900; Rush Service (Telephone Orders Only) 800-553-6847; Website: http://www.ntis.gov
- Keywords
-
fire endurance
|
fire tests
|
flame through
|
floors
|
furniture
|
interior finishes
|
joists
|
room fires
|
steels
|
wood
- Abstract
- A series of seven large-scale room burnout fire tests was conducted with a set of selected residential floor-ceiling assemblies to provide data on the performance of the assemblies; these will be compared with the results in future tests on the same constructions in a fire endurance furnace. Four wood-frame and three light gage steel-frame, load-bearing assemblies, each measuring 3.7 x 3.7 m in size, were exposed from the underside to a fire environment produced from the burning of typical furniture and interior finish materials in a room. the fire resistance periods based on flame-through of floor assembly and structural failure of floor joists varied from 10 to 12 minutes for floors with unprotected wood joists and was 4 minutes or less for floors with unprotected steel joists. The addition of a 12.7 mm thick gypsum board ceiling as a protective layer increased the fire resistance time of the steel joisted floor assembly approximately 12 minutes.