- Author
- Remesh, K. | Tan, K. H.
- Title
- Field Model Analysis and Experimental Assessment of Fire Severity and Smoke Movement in a Partitioned and a Non-Partitioned Dwelling Unit.
- Coporate
- Nanyang Technological Univ., Singapore
- Journal
- Journal of Fire Sciences, Vol. 24, No. 5, 365-391, September 2006
- Keywords
- residential buildings | field models | fire severity | smoke movement | compartment fires | equations | conservation | combustion models | heat release rate | thermocouples | temperature | fire load | experiments | computational fluid dynamics
- Identifiers
- experimental measurement; non-partitioned (NP) unit; partitioned (PT) unit; CFAST (Consolidated Fire growth And Smoke Transport); dimensions of the compartment openings; conservation of mass; conservation of species; conservation of momentum; conservation of energy; estimated heat release rate of wooden crib fire; plan locations of thermocouple trees (distances from the right hand side bottom corner of the building unit); parameters of interest for comparison in the PT and NP experiments