Fire-Endurance and Hose-Stream Tests of Wood-Framed Partitions With Facings of Gypsum-Perlite Plaster on Gypsum Lath.
Coporate
National Bureau of Standards, Washington, DC
Report
Test 251; Test 252; TR10219-78; FP2931
June 1, 1950
20 p.
Keywords
fire endurance tests | hoses | wood | partitions | gypsum | plaster
Abstract
A wood-framed load-bearing partition, 16 ft wide and 10 ft 4 in. high, with facings of 1/2 in of gypsum-perlite plaster on 3/8-in perforated gypsum lath, was subjected to a fire-endurance test No. 251, on October 20, 1949. A 10-ft square partition of the same construction was subjected to a fire and hose-stream test No. 252, on October 21, 1949. The partitions were tested in cooperation with the Gypsum Association to establish a fire-resistance rating for the particular construction.