FireDOC Search

Author
Ryan, J. V. | Bender, E. W.
Title
Fire Endurance of Open-Web Steel-Joist Floors With Concrete Slabs and Gypsum Ceilings.
Coporate
National Bureau of Standards, Washington, DC
Report
BMS 141
August 23, 1954
19 p.
Keywords
floors | joists | steels | concrete slabs | gypsum | ceilings | fire tests | plaster
Identifiers
open-web steel-joist floors; gypsum-perlite plaster
Abstract
The results presented were obtained in a program of 18 fire tests on open-web steel-joist floors, 16 of which were protected by ceilings of gypsum-perlite plaster on gypsum lath "furred" directly to the joists. Variables included plaster thickness, plaster mixes, spacing of furring channels, system of lath clips, reinforcing in the ceilings, and type floor slab. An acoustical plaster finish was applied to one ceiling. The range of fire endurances obtained, from 1 hour to 4 hours 26 minutes, was sufficient to cover the requirements for floors in many building codes. The importance of the ceiling's protective function was demonstrated in two tests without ceilings, in each of which failure occurred at 7 minutes.