FireDOC Search

Author
Fanney, A. H.
Title
Field Monitoring of a Variable-Speed Integrated Heat Pump/Water-Heating Appliance.
Coporate
National Institute of Standards and Technology, Gaithersburg, MD
Journal
ASHRAE Transactions, Vol. 101, No. 2, 1-15, 1995
Report
Paper 3888,
Keywords
heat pumps | integrated water heating | field study | building technology | coefficient of performance | combined performance factor | HSPF | peak demand | SEER | thermal performance | variable speed | electrical power
Abstract
A variable-speed integrated heat pump/water heating appliance was monitored for two years while meeting the space-conditioning and water-heating needs of an occupied residence. Experimental results are presented that show the total energy consumed by the residence was significantly reduced compared to previous years in which electric baseboard heat, a wood stove, and window air conditioners were used. During the two space-heating seasons, the variable-speed integrated heat pump/water heating appliance used 60% less energy than would have been consumed by an electric furnace with the same air distrubition system and a storage-type electric water heater. The monthly space-cooling-only coefficients of performance (COP) ranged from 2.50 to 4.03, whereas the monthly space-heating-only coefficients of performance ranged from a low of 0.91 to a high of 3.33. A proposed index to quantify the overall system performance of integrated water-heating/space-conditioning appliances, referred to as the combined performance factor, ranged from 1.55 to 3.50. The majority of larger values occurred during months in which space cooling dominated. The combined performance factor for the entire two-year study was 2.45. A conventional watt hour meter supplied by the local electrical utility and an electronic digital power analyzer were used to measure the energy consumption of the variable-speed heat pump to discern if variable-speed equipment introduces errors in conventional utility metering equipment. Measurements made using the two instruments were in excellent agreement. The monthly energy consumption and peak electrical demands of the residence, integrated heat pump/water-heating appliance, supplemental space heater, and water heater are discussed. The influence of outdoor temperature on electrical power demand is presented.