FireDOC Search

Author
Carlsson, G. | Wistedt, I.
Title
Analysis of Arson Accelerant Residues by ATD 400.
Coporate
SKL-National Laboratory of Forensic Science, Linkoping, Sweden
Report
Report 26, March 15, 1993, 13 p.
Keywords
arson | accelerants | residues | debris fires
Identifiers
detection limits; overloading
Abstract
The Perkin Elmer Automatic Thermal Desorption System ATD-400 was studied as a means of automating the analyses of arson accelerants in fire debris. With tenax TA as adsorbent, detection limits were determined for the most frequently used arson accelerants. The effects of overloading the system was also studies. Using a "sniffer" we determined the optimum conditions for analyses of fire debris. With the ATD-400 system up to 25 samples a day could be handled and thus a more efficient laboratory routine for arson analysis was obtained.