- Author
- Christian, W. J.
- Title
- Effect of Structural Characteristics on Dwelling Fire Fatalities.
- Coporate
- Underwriters Laboratories, Inc., Northbrook, IL
- Journal
- Fire Journal, Vol. 68, No. 1, 22-28, January 1974
- Keywords
- residential buildings | fire fatalities | fire safety | fire statistics
- Identifiers
- materials first ignitied in Oregion Residential Buildings; factors contribution to 119 conflagrations in the United States and Canada since 1900; primary causes of dwelling fire deaths; reasons for failure to escape from dewlling fires; factors responsible for spread of smoke and fire resulting in loss of life in dwellings; equivalent duration of ASTM E 119 standard fire for various experimental fires; time burning before detection Oregon dwelling fires; effects of closed door on limiting survival time in a room beyond (min.); building separation distances for protection against radiation from window openings of burning building; horizontal separation required to protect against flames through the roof of an exposing building fire