- Author
-
Sugawa, O.
|
Tobari, M.
- Title
- Behavior of Flame/Plume Flow In and Near Corner Fire: Entrainment Coefficient for Corner Fire.
- Coporate
- Science University of Tokyo, Japan
Data Communication system, Co., Ltd., Japan
- Report
-
NISTIR 6588
November 2000
- Distribution
- AVAILABLE FROM National Technical Information Service (NTIS), Technology Administration, U.S. Department of Commerce, Springfield, VA 22161. Telephone: 1-800-553-6847 or 703-605-6000; Fax: 703-605-6900; Rush Service (Telephone Orders Only) 800-553-6847; Website: http://www.ntis.gov
- Book or Conf
- U.S./Japan Government Cooperative Program on Natural Resources (UJNR). Fire Research and Safety. 15th Joint Panel Meeting. Volume 2. Proceedings. March 1-7, 2000,
San Antonio, TX,
Bryner, S. L., Editors,
489-493 p.,
2000
- Keywords
-
fire safety
|
fire research
|
corners
|
air entrainment
|
mass flux
|
heat release rate
|
flame height
|
temperature
|
velocity
|
carbon dioxide
|
flame length
- Identifiers
- layout of the fire source in and near corner; cross section of the flame and plume area; mass flux along the trajectoryling; averaged CO2 gas concentration and averaged excess temperature along the trajectory; flame height in and near corner