Lie, T. T.
Title
Feasibility of Determining the Equilibrium Moisture Condition in Fire Resistance Test Specimens by Measuring Their Electrical Resistance.
Coporate
National Research Council of Canada, Ottawa, Ontario
Report
Building Research Note No. 75, March 1971, 12 p.
Keywords
fire resistance tests | electrical resistance | moisture | concretes
Abstract
For fire resistance test specimens the moisture condition within the specimen, before testing, should be approximately the same as that of a similar construction in service. According to ASTM fire test specification E 119-69, such a condition is reached when the moisture content of the specimen becomes equal to that which would be established at equilibrium in an atmosphere of 50 to 75% relative humidity and 73 ± 5 deg F temperature.