Bill, R. G., Jr.; Namer, I.; Cheng, R. K.; Robben, F.; Talbot, L.
view article (1.0)
Flame Propagation in Grid Induced Turbulence.
LBL-10416,
March 1980,
2 p.
Lawrence Berkeley Lab. Combustion Research--FY 1979. March 1980.,
6/29-6/30 p.,
1980
Cheng, R. K.; Bill, R. G., Jr.; Ng, T. T.; Robben, F.; Talbot, L.
view article (1.0)
Combustion in a Turbulent Boundary Layer.
LBL-10416,
March 1980,
3 p.
Lawrence Berkeley Lab. Combustion Research--FY 1979. March 1980.,
6/30-6/32 p.,
1980
Namer, I.; Bill, R. G., Jr.; Robben, F.; Talbot, L.
view article (1.0)
Interaction of a Flame With a Karman Vortex Street.
LBL-10416,
March 1980,
2 p.
Lawrence Berkeley Lab. Combustion Research--FY 1979. March 1980.,
6/41-6/42 p.,
1980
Bill, R. G., Jr.; Namer, I.; Talbot, L.; Robben, F.
view article (1.0)
Density Fluctuations of Flames in Grid-Induced Turbulence.
California Univ., Berkeley
Combustion and Flame,
Vol. 44,
No. 1-3,
277-285,
January 1982
Bill, R. G., Jr.; Kung, H. C.; Brown, W. R.; Hill, E. E., Jr.
view article (1.0)
Evaluation of Extended Coverage, Sidewall Sprinklers and Smoke Detectors in a Hotel Occupancy. Technical Report.
Factory Mutual Research, Norwood, MA
Journal of Fire Protection Engineering,
Vol. 1,
No. 3,
77-98,
1989
U.S. Fire Administration, Washington, DC,
FMRC J.I.0M3N5.RA(4),
May 1988,
87 p.
Bill, R. G., Jr.
view article (1.0)
Response of Smoke Detectors to Smoldering-Started Fires in a Hotel Occupancy. Technical Report.
Factory Mutual Research Corp., Norwood, MA
Federal Emergency Management Agency, Washington, DC; National Electrical Manufacturers Assoc., Washington, DC,
FMRC J.I. 0Q0R4.RA,
November 1988,
72 p.
Heskestad, G.; Bill, R. G., Jr.
view article (1.0)
Modeling of Thermal Responsiveness of Automatic Sprinklers.
Factory Mutual Research Corp., Norwood, MA
U.S./Japan Government Cooperative Program on Natural Resources (UJNR). Fire Research and Safety. 10th Joint Panel Meeting. June 9-10, 1988,
Tsukuba, Japan,
140-141 p.,
1988
Bill, R. G., Jr.; Kung, H. C.; Brown, W. R.; Hill, E. E., Jr.
view article (1.0)
Effects of Cathedral and Beamed Ceiling Construction on Residential Sprinkler Performance.
Factory Mutual Research Corp., Norwood, MA
International Association for Fire Safety Science. Fire Safety Science. Proceedings. 2nd International Symposium. June 13-17, 1988,
Hemisphere Publishing Corp., New York,
Tokyo, Japan,
Wakamatsu, T.; Hasemi, Y.; Sekizawa, A.; Seeger, P. G.; Pagni, P. J.; Grant, C. E., Editors,
643-653 p.,
1989
Bill, R. G., Jr.
view article (1.0)
Life Safety Team: Smoke Detectors and Sprinklers in Hotels.
Factory Mutual Research Corp., Norwood, MA
Fire Journal,
Vol. 84,
No. 3,
28-31,34-35,37,
May/June 1990
RC89-TP-9; OR2E5.RA,
August 1989,
20 p.
Bill, R. G., Jr.; Kung, H. C.; Vincent, B. G.; Brown, W. R.; Hill, E. E., Jr.
view article (1.0)
Predicting the Suppression Capability of Quick Response Sprinklers in a Light Hazard Scenario. Part 2. Actual Delivered Density (ADD) Measurements and Full-Scale Fire Tests.
Factory Mutual Research Corp., Norwood, MA
Journal of Fire Protection Engineering,
Vol. 3,
No. 3,
95-107,
July/August/September 1991
U.S. Fire Administration, Washington, DC,