displaying 1 - 10 results in total 16
House, J. M.; Smith, T. F.
view article (1.0)System Approach to Optimal Control for HVAC and Building Systems.Iowa Univ., Iowa CityASHRAE Transactions, Vol. 101, No. 2, 1995Iowa Energy Center, Iowa City, SD-95-3-1; Project 92-05; Project 9302-01,Seem, J. E.; House, J. M.
view article (1.0)Control System That Prevents Air From Entering an Air-Handling Unit Through the Exhaust Air Damper.Johnson Controls, Inc., Milwaukee, WI; National Institute of Standards and Technology, Gaithersburg, MDOptimum Ventilation and Air Flow Controls in Buildings. AIVC 17th Annual Conference. Proceedings. Volume 2. September 1996, Gothenberg, Sweden, 562-569 p., 1996Lee, W. Y.; Park, C.; House, J. M.; Kelly, G. E.
view article (1.0)Fault Diagnosis of an Air-Handling Unit Using Artificial Neural Networks.Korea Institute of Energy Research, Taejon, South Korea; National Institute of Standards and Technology, Gaithersburg, MDASHRAE Transactions, Vol. 102, No. 1, 540-549, 1996AT-96-3-3,Fault Detection and Diagnosis for HVAC Systems Symposium. Part 1. Proceedings. American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE). February 17-21, 1995, Atlanta, GA, ['1995', '1996']Lee, W. Y.; House, J. M.; Shin, D. R.
view article (1.0)Fault Diagnosis and Temperature Sensor Recovery for an Air-Handling Unit.Korea Institute of Energy Research, Taejon, Korea; National Institute of Standards and Technology, Gaithersburg, MDASHRAE Transactions, Vol. 103, No. 1, [pages unknown], 1997Seem, J. E.; House, J. M.; Monroe, R. H.
view article (1.0)On-Line Monitoring and Fault Detection of Control System Performance.Johnson Controls, Inc., Milwaukee, WI; National Institute of Standards and Technology, Gaithersburg, MDCLIMA 2000 Conference, Proceedings. August 30-September 2, 1997, Brussels, Belgium, 1-20 p., 1997Seem, J. E.; House, J. M.; Klaassen, C. J.
view article (1.0)Volume Matching Control: Leave the Outdoor Air Damper Wide Open.Johnson Controls, Inc., Milwaukee, WI; National Institute of Standards and Technology, Gaithersburg, MD; Iowa Energy Center, Ankeny, IOASHRAE Journal, Vol. 40, No. 2, 58-60, February 1998Seem, J. E.; Park, C.; House, J. M.
view article (1.0)New Sequencing Control Strategy for Air-Handling Units.Johnson Controls, Inc., Milwaukee, WI; National Institute of Standards and Technology, Gaithersburg, MDHVAC&R Research, Vol. 5, No. 1, 35-58, January 1999Seem, J. E.; House, J. M.; Monroe, R. H.
view article (1.0)On-Line Monitoring and Fault Detection.Johnson Controls, Inc., Milwaukee, WI; National Institute of Standards and Technology, Gaithersburg, MDASHRAE Journal, Vol. 41, No. 7, 21-26, July 1999House, J. M.; Lee, W. Y.; Shin, D. R.
view article (1.0)Classification Techniques for Fault Detection and Diagnosis of an Air-Handling Unit.National Institute of Standards and Technology, Gaithersburg, MD; Korea Institute of Energy Research, Taejon, KoreaASHRAE Transactions, Vol. 105, No. 1, 1987-1997, 1999CH-99-18-5,House, J. M.; Kelly, G. E.
view article (1.0)Overview of Building Diagnostics.National Institute of Standards and Technology, Gaithersburg, MDNational Conference on Building Commissioning. Proceedings. May 3-5, 2000, Kansas City, MO, 2000. AND Diagnostics for Commercial Buildings: Research to Practive. Proceedings. June 16-17, 1999, San Francisco, CA, 16-17 pp, 1999, 1-9 p., ['2000', '1999']