FireDOC Search

displaying 1 - 7 results in total 7

  • Babrauskas, V.
    view article (10.004545)

    Ten Years of Heat Release Research With the Cone Calorimeter.
    National Institute of Standards and Technology, Gaithersburg, MD
    CIB W14/93/2 (J),
    Tsukuba Building Test Laboratory, Center for Better Living. Japan Symposium on Heat Release and Fire Hazard, First (1st) Proceedings. Session 3. Scope for Next-Generation Fire Safety Testing Technology. May 10-11, 1993, Tsukuba, Japan, III/1-8 p., 1993

  • Yoshida, K.
    view article (9.986072)

    Evaluation of Sprinkler Systems for Ships Based on Heat Release Rate.
    Research Institute of Marine Engineering, Higashimurayama, Tokyo
    CIB W14/93/2 (J),
    Tsukuba Building Test Laboratory, Center for Better Living. Japan Symposium on Heat Release and Fire Hazard, First (1st) Proceedings. Session 3. Scope for Next-Generation Fire Safety Testing Technology. May 10-11, 1993, Tsukuba, Japan, III/57-64 p., 1993

  • Kallonen, R.; Mikkola, E.
    view article (9.58703)

    Burning Characteristics and Toxicity Data for Some Products Used in Buildings.
    VTT-Technical Research Center of Finland, Espoo
    CIB W14/93/2 (J),
    Tsukuba Building Test Laboratory, Center for Better Living. Japan Symposium on Heat Release and Fire Hazard, First (1st) Proceedings. Session 3. Scope for Next-Generation Fire Safety Testing Technology. May 10-11, 1993, Tsukuba, Japan, III/9-13 p., 1993

  • Ostman, B. A. L.; Tsantaridis, L. D.
    view article (9.58703)

    Correlations Between Cone Calorimeter Data and Time to Flashover in the Room Fire Test.
    Swedish Institute for Wood Technology Research, Stockholm, Sweden
    CIB W14/93/2 (J),
    Tsukuba Building Test Laboratory, Center for Better Living. Japan Symposium on Heat Release and Fire Hazard, First (1st) Proceedings. Session 3. Scope for Next-Generation Fire Safety Testing Technology. May 10-11, 1993, Tsukuba, Japan, III/37-44 p., 1993

  • Hshieh, F. Y.; Motto, S. E.; Hirsch, D. B.; Beeson, H. D.
    view article (9.30499)

    Flammability Testing of Materials in Oxygen-Depleted and Oxygen-Enriched Environments Using a Controlled-Atmosphere Cone Calorimeter.
    Lockheed, Las Cruces, NM; National Aeronautics and Space Administration, White Sands Testing Facility, NM
    CIB W14/93/2 (J),
    Tsukuba Building Test Laboratory, Center for Better Living. Japan Symposium on Heat Release and Fire Hazard, First (1st) Proceedings. Session 3. Scope for Next-Generation Fire Safety Testing Technology. May 10-11, 1993, Tsukuba, Japan, III/15-24 p., 1993

  • Grand, A. F.
    view article (9.30499)

    Laboratory Investigations of Fire Resistant Coatings on Glass-Reinforced Polymeric Composite Products.
    Omega Point Laboratories, San Antonio, TX
    CIB W14/93/2 (J),
    Tsukuba Building Test Laboratory, Center for Better Living. Japan Symposium on Heat Release and Fire Hazard, First (1st) Proceedings. Session 3. Scope for Next-Generation Fire Safety Testing Technology. May 10-11, 1993, Tsukuba, Japan, III/25-36 p., 1993

  • Grayson, S. J.; Hirschler, M. M.
    view article (9.30499)

    Investigation Into the Use of Heat Release Calorimetry for Testing Electrical Cables.
    Queen Mary and Westfield College, London, England; Safety Engineering Laboratories, Rocky River, OH
    CIB W14/93/2 (J),
    Tsukuba Building Test Laboratory, Center for Better Living. Japan Symposium on Heat Release and Fire Hazard, First (1st) Proceedings. Session 3. Scope for Next-Generation Fire Safety Testing Technology. May 10-11, 1993, Tsukuba, Japan, III/45-50 p., 1993