FireDOC Search

displaying 1 - 10 results in total 133

  • Cooper, L. Y.; Stroup, D. W.
    view article (7.508707)

    Test Results and Predictions for the Response of Near-Ceiling Sprinkler Links in a Full-Scale Compartment Fire.
    National Bureau of Standards, Gaithersburg, MD
    U.S. Fire Administration, Emmitsburg, MD, NBSIR 87-3633, September 1987, 45 p.
    International Association of Fire Safety Science. Fire Safety Science. Proceedings. 2nd International Symposium. June 13-17, 1988, Hemisphere Publishing Corp., New York, Tokyo, Japan, Wakamatsu, T., Hasemi, Y., Sekizawa, A., Seeger, P. G., Pagni, P. J. and Grant, C. E., Editors, 623-632 p., 1989

  • Motevalli, V.; Marks, C. H.
    view article (7.508707)

    Scaling of Unconfined Ceiling Jet Velocity and Temperature Measurements.
    Worcester Polytechnice Inst., MA; Maryland Univ., College Park
    Combustion Institute/Eastern States Section. Chemical and Physical Processes in Combustion. 1988 Technical Meeting. December 5-7, 1988, Clearwater Beach, FL, 62/1-4 p., 1988

  • Cooper, L. Y.
    view article (7.508707)

    Heat Transfer in Compartment Fires Near Regions of Ceiling-Jet Impingement on a Wall.
    National Institute of Standards and Technology, Gaithersburg, MD
    Journal of Heat Transfer, Vol. 111, 455-460, May 1989

  • International Association for Fire Safety Science
    view article (7.508707)

    Fire Safety Science. Proceedings. 2nd (Second) International Symposium. June 13-17, 1988.
    International Association for Fire Safety Science. Fire Safety Science. Proceedings. 2nd (Second) International Symposium. June 13-17, 1988, Hemisphere Publishing Corp., New York, Tokyo, Japan, Wakamatsu, T.; Hasemi, Y.; Sekizawa, A.; Seeger, P. G.; Pagni, P. J.; Grant, C. E., Editors, 972 p., 1989

  • Marrion, C. E.
    view article (7.508707)

    Lag Time Modeling and Effects of Ceiling Jet Velocity on the Placement of Optical Smoke Detectors.
    Worcester Polytechnic Institute, MA
    Thesis, December 1989, 226 p.

  • Ricciuti, C.
    view article (7.508707)

    Characterization of Confined Fire-Plume-Driven Ceiling Jets.
    Worcester Polytechnic Inst., MA
    Thesis, June 1991, 145 p.

  • Yuan, Z. P.; Motevalli, V.
    view article (7.508707)

    Steady State Ceiling Jet Behavior Under an Unconfined Ceiling With Beams.
    Worcester Polytechnic Inst., MA
    SFPE Bulletin, 6-12, September/October 1994

  • Yuan, Z. P.; Motevalli, V.
    view article (7.508707)

    Steady State Temperature Profiles Under a Beamed Ceiling.
    Worcester Polytechnic Inst., MA
    NISTIR 5499, September 1994,
    National Institute of Standards and Technology. Annual Conference on Fire Research: BOOK OF ABSTRACTS. October 17-20, 1994, Gaithersburg, MD, 89-90 p., 1994

  • Ricciuti, C.; Motevalli, V.
    view article (7.508707)

    Transient Confined Ceiling Jet Characteristics in the Presence of an Upper Layer.
    Worcester Polytechnic Inst., MA
    Combustion Institute/Eastern States Section. Chemical and Physical Processes in Combustion. Proceedings. Fall Technical Meeting, 1991. October 14-16, 1991, Ithaca, NY, 85/1-4 p., 1991

  • Mangs, J.; Keski-Rahkonen, O.
    view article (7.508707)

    Fire Safety for Open Car Park Buildings.
    VTT-Technical Research Center of Finland, Espoo
    TNO Building and Construction Research. CIB/W14 Workshop, 3rd. Fire Engineering Workshop on Modelling. Proceedings. January 25-26, 1993, Delft, The Netherlands, Twilt, L., Editors, 206-213 p., 1993