displaying 1 - 10 results in total 58
Issen, L. A.; Gustaferro, A. H.; Carlson, C. C.
view article (1.0)Fire Tests of Concrete Members: An Improved Method for Estimating Thermal Restraint Forces.National Bureau of Standards, Gaithersburg, MD; Portland Cement Assoication, Skokie, ILASTM SP 464, 1969, 34 p.American Society for Testing and Materials. Fire Test Performance. Winter Meeting. Proceedings. ASTM STP 464. February 2-7, 1969, American Society for Testing and Materials, Philadelphia, PA, 153-185 p., 1969Issen, L. A.
view article (1.0)Analytic Model for Calculating the Fire Resistance of Simply Supported Prestressed and Reinforced Concrete Beams.National Bureau of Standards, Gaithersburg, MDNBS SP 411,National Bureau of Standards. Fire Safety Research. Proceedings of a Symposium. August 22, 1973., Gaithersburg, MD, 154-164 p., 1973Bresler, B.; Iding, R. H.
view article (1.0)Fire Response of Prestressed Concrete Members.Wiss, Janney, Elstner and Associates, Emeryville, CAFire Safety of Concrete Structures. ACI Committee 216. September 1980, San Juan, Puerto Rico, Abrams, M. S., Editors, 69-114 p., 1983Haksever, A.; Kordina, K.
view article (1.0)Fire Engineering Design of the New "Reichsbrucke" in Vienna.Technical Univ., Braunschweig, West GermanyFire Safety of Concrete Structures. ACI Committee 216. September 1983, San Juan, Puerto Rico, Abrams, M. S., Editors, 177-200 p., 1983Gustaferro, A.
view article (1.0)Experiences From Evaluating Fire-Damaged Concrete Structures.Consulting Engineers Group, Inc., Glenview, ILFire Safety of concrete Structures. ACI Committee 216. September 1980, San Juan, Puerto Rico, Abrams, M. S., Editors, 269-278 p., 1983Gustaferro, A. H.; Abrams, M. S.; Salse, E. A. B.
view article (1.0)Fire Resistance of Prestressed Concrete Beams. Study C: Structural Behavior During Fire Tests. PCA Research and Development Bulletin.Portland Cement Association, Skokie, ILBulletin RD009.01B; PCA R/D Ser. 1475-1, 1971, 29 p.Gustaferro, A. H.
view article (1.0)Design of Prestressed Concrete for Fire Resistance.Consulting Engineers Group, Inc., Glenview, ILno date, 12 p.Haksever, A.
view article (1.0)Fire Response of Total Systems in a Local Fire.T. U. Braunschweig, West GermanyFire Safety Journal, Vol. 4, No. 3, 141-146, 1981/1982Abrams, M. A.; Cruz, C. R.
view article (1.0)Behavior at High Temperature of Steel Strand for Prestressed Concrete.Portland Cement Assoc., Skokie, ILJournal of the PCA Research and Development Laboratories, Vol. 3, No. 3, 8-19, September 1961Kristen, T.; Wierig, H. J.
view article (1.0)Effect of High Temperatures on Prestressed Concrete Structural Units.Der Bauingenieur, Vol. 35, No. 1, 6-11, 1960