FireDOC Search

displaying 1 - 10 results in total 30

  • Wright, R. N.
    view article (9.300467)

    Structural Analysis in Context.
    National Institute of Standards and Technology, Gaithersburg, MD
    American Society of Civil Engineers (ASCE). Structural Engineering in Natural Hazards Mitigation. Structures Congress '93 Proceedings. Volume 2. April 19-21, 1993, Am. Soc. of Civil Engineers, New York, NY, Irvine, CA, Ang, A. H. S.; Villaverde, R., Editors, 1657-1662 p., 1993

  • Zhao, B.; Kruppa, J.
    view article (9.300467)

    Structural Behavior of an OpenCar Park Under Real Fire Scenarios.
    CTICM, Fire and Testing Division, Saint-Remy-Les-Chevreuse, France
    Fire and Materials, Vol. 28, No. 2/4, 269-280, March/August 2004

  • Forster, S.; Chladna, M.; Hsieh, C.; Burgess, I.; Plank, R.
    view article (9.300467)

    Thermal and Structural Behavior of a Full-Scale Composite Building Subject to a Severe Compartment Fire.
    Sheffield Univ., UK; Slovak Technical Univ., Bratislava; Buro Happold FEDRA, Leeds, UK
    Fire Safety Journal, Vol. 42, No. 3, 183-199, April 2007

  • Yancey, C. W. C.; Cheok, G. S.; Sadek, F.; Mohraz, B.
    view article (8.899525)

    Summary of the Structural Performance of Single-Family, Wood-Frame Housing.
    National Institute of Standards and Technology, Gaithersburg, MD
    NISTIR 6224, September 1998, 168 p.

  • Usmani, A. S.; Lamont, S.
    view article (8.899525)

    Key Events in the Structural Response of a Composite Steel Frame Structure in Fire.
    Edinburgh Univ., Scotland; Arup Fire, Ove-Arup & Partners, London, England
    Fire and Materials, Vol. 28, No. 2/4, 281-297, March/August 2004

  • Wu, B.; Xu, Y. Y.
    view article (8.899525)

    Behavior of Axially-and-Rotationally Restrained Concrete Colums With '+'-Shaped Cross Section and Subjected to Fire.
    South China University of Technology, Guangzhou 510640, People's Republic of China; Huaqiao Universtiy, Quanzhou, Fujian Province 362021, People's Republic of China
    Fire Safety Journal, Vol. 44, No. 2, 212-218, February 2009

  • Wu, B.; Li, Y. H.; Chen, S. L.
    view article (8.899525)

    Effect of Heating and Cooling on Axially Restrained RC Columns With Special-Shaped Cross Section.
    South China University of Technology, 510640 Guangzhou, China
    Fire Technology, Vol. 46, No. 1, 231-249, January 2010

  • Jonsdottir, A.; Rein, G.
    view article (8.899525)

    Out of Range.
    Fire Risk Management, 14-17, December 2009

  • Raufaste, N. J., Jr.
    view article (8.739733)

    NIST Building and Fire Research Laboratory Projects, 1993.
    National Institute of Standards and Technology, Gaithersburg, MD
    NIST SP 838-1; PB94-118288, August 1993, 129 p.

  • Gross, J. L.; Hervey, F.; Izydorek, M.; Mammoser, J.; Treadway, J.
    view article (8.739733)

    Fire Resistance Tests of the Floor Truss Systems. Federal Building and Fire Safety Investigation of the World Trade Center Disaster.
    National Institute of Standards and Technology, Gaithersburg, MD; Underwriters Laboratories, Inc., Northbrook, IL
    NIST NCSTAR 1-6B, September 2005, 202 p.