U.S. House of Representatives. 101st Congress. 1st Session.
view article (4.8805814)
Hotel and Motel Fire Safety Act of 1989.
House of Representatives, Washington, DC
H.R. 94,
January 3, 1989,
9 p.
O'Hagan, J. T.
view article (4.8805814)
Sprinkler Heat Closes Automatically After Putting Fire Under Control.
Fire Engineering,
Vol. 131,
No. 12,
27-28,
December 1978
Young, R. A.; Nash, P.
view article (4.8805814)
Fire Protection of Modern High Bay Storages.
Fire Insurers' Research and Testing Organization, Borehamwood, England
Fire Prevention, Science, and Technology,
No. 18,
4-13,
December 1977
Moore, J.
view article (4.8805814)
Why Sprinkler Systems.
Fire Engineering,
Vol. 142,
No. 4,
36-40,
April 1989
Willey, A. E.; Nesbitt, F. H.; Hilton, D.; Reiss, M. H.
view article (4.8805814)
Statements of A. Ellwood Willey, Assistant Vice President, Research and Fire Information Services, National Fire Protection Association, Quincy, Massachusetts; Frederick H. Nesbit, Legislative and Political Representative, International Association of Fire Fighters, Washington, D. C.; David Hilton, Second Vice President, International Association of Fire Chiefs, Washington, D. C.; and Martin H. Reiss, Chairman of the Board, The Gamewell Corporation, Representing the National Electrical Manufacturers Association, Medway, Massachusetts.
National Fire Protection Assoc., Quincy, MA; International Association of Fire Fighters, Washington, DC; International Association of Fire Chiefs, Washington, DC; National Electrical Manufacturers Assoc., Medway, MA
No. 6,
March 2, 1989,
U.S. House of Representatives. 101 Congress. 1st Session. Hotel and Motel Fire Safety Act of 1989. March 2, 1989,
31-276 p.,
1989
Yao, C.
view article (4.8805814)
Development of Large-Drop Sprinklers (0.64-in. Orifice Diameter).
Factory Mutual Research Corp., Norwood, MA
RC76-T-18,
U.S./Japan Government Cooperative Program on Natural Resources (UJNR). Panel on Fire Research and Safety. Volume 3. Building System. October 19-22, 1976,
Tokyo, Japan,
1-37 p.,
1976
Building Official and Code Administrator
view article (4.8805814)
Sprinklers Inoperable in $10 Million Art Gallery Fire.
Building Official and Code Administrator,
Vol. 23,
No. 3,
33,
May/June 1989
Suzuki, H.
view article (4.8805814)
Progress Report on Fire Risk and Hazard Modeling in Japan.
Building Research Institute, Ibaraki-ken, Japan
U.S./Japan Government Cooperative Program on Natural Resources (UJNR). Fire Research and Safety. 10th Joint Panel Meeting. June 9-10, 1988,
Tsukuba, Japan,
60-64 p.,
1988
Building Research Association of New Zealand
view article (4.8805814)
Residential Fire Sprinklers.
Building Research Association of New Zealand, Porirua
BRANZ Building Info. Bull. 262,
1989,
6 p.
Rogers, S. P.; Young, R. A.
view article (4.8805814)
Protection of High-Racked Storages by Commercial Zoned Sprinkler Systems.
Fire Research Station, Borehamwood, England
FR Note 1068,
April 1977,
25 p.