FireDOC Search

displaying 121 - 130 results in total 174

  • Morgan, H. P.
    view article (7.049175)

    Philosophy of Smoke Control.
    Fire Engineers Journal, Vol. 61, No. 213, 14-18, July 2001

  • Watanabe, Y.; Matsushima, S.; Yamada, T.
    view article (7.049175)

    Experimental Study on Pressurization Smoke Control by Using a Medium-Size Model. Part 1. Prediction of Hot Layer Temperature and Exhaust Efficiency in Fire Room.
    Japan Weather Association, Tokyo, Japan
    Bulletin of Japan Association for Fire Science and Engineering, Vol. 51, No. 2, 29-40, 2001

  • Watanabe, Y.; Matsushima, S.; Yamada, T.
    view article (7.049175)

    Experimental Study on Pressurization Smoke Control by Using a Medium-Size Model. Part 2. Prediction of Height of Hot Layer Bottom Based on Plume Flow Rate Within Intermittent Flame Region.
    National Research Institute of Fire and Disaster, Tokyo, Japan
    Bulletin of Japan Association for Fire Science and Engineering, Vol. 51, No. 2, 41-50, 2001

  • Kealy, M.
    view article (7.049175)

    Fire Engineering of Tall Buildings Lessons Learned From 9/11.
    WSP Fire, London, England
    Strategies for Performance in the Aftermath of the World Trade Center. CIB-CTBUH Conference on Tall Buildings. Proceedings. Task Group on Tall Buildings: CIB TG50. CIB Publication No. 290. October 20-23, 2003, Kuala Lumpur, Malaysia, Shafii, F.; Bukowski, R.; Klemencic, R., Editors, 673-679 p., 2003

  • Razza, J. C.; Grill, R. A.
    view article (7.049175)

    Amendments to the Fire Protection and Life Safety Provisions of the New York City Building Code by Local Laws Adopted While World Trade Center 1, 2, and 7 Were in Use. Federal Building and Fire Safety Investigation of the World Trade Center Disaster.
    Rolf Jensen and Associates, Inc., Deerfield, IL
    NIST NCSTAR 1-1G, September 2005, 54 p.

  • Bellido, C.; Quiroz, A.; Panizo, A.; Torero, J. L.
    view article (7.049175)

    Performance Assessment of Pressurized Stairs in High Rise Buildings.
    Engineering Services, SAC, Lima, PerĂº; Edinburgh Univ., Scotland
    Fire Technology, Vol. 45, No. 2, 189-200, June 2009

  • Chow, W. K.
    view article (7.049175)

    Retrospective Survey on Elevator Evacuation of Supertall Buildings Under Fires.
    Hong Kong Polytechnic Univ., China
    Journal of Applied Fire Science, Vol. 16, No. 4, 315-327, 2006-2007

  • Klote, J. H.
    view article (6.8200827)

    Smoke Control at Veterans Administration Hospitals.
    National Bureau of Standards, Gaithersburg, MD
    Veterans Admin., Washington, DC, NBSIR 85-3297, January 1986, 108 p.

  • Klote, J. H.
    view article (6.8200827)

    Computer Program for Analysis of Pressurized Stairwells and Pressurized Elevator Shafts.
    National Bureau of Standards, Gaithersburg, MD
    NIST SP 983; NBSIR 80-2157, May 2002; January 1981, 85 p.
    Collected Publications Related to the Use of Elevators During Fires. NIST SP 983. May 2002, Bukowski, R. W.; Burgess, S. R.; Reneke, P. A., Editors, ['2002', '1981']

  • Schmidt, W.; Klote, J. H.
    view article (6.8200827)

    In Case of Fire: Use the Stairwells, Elevators Aren't Safe.
    Veterans Administration, Washington, DC; National Bureau of Standards, Gaithersburg, MD
    Specifying Engineer, Vol. 47, No. 5, 82-86, May 1982