FireDOC Search

displaying 151 - 160 results in total 373

  • Lie, T. T.; Celikkol, B.
    view article (1.0)

    Method to Calculate the Fire Resistance of Circular Reinforced Concrete Columns.
    National Research Council of Canada, Ottawa, Ontario
    ['IRC Paper 1951', 'NRCC 34917', 'Title 88-M12']
    ACI Materials Journal, Vol. 88, No. 1, 84-91, January/February 1991
    IRC Paper 1951; NRCC 34917; Title 88-M12

  • Lie, T. T.; Macaulay, B. A.
    view article (1.0)

    Evaluation of the Fire Resistance of Protected Steel Columns.
    National Research Council of Canada, Ottawa, Ontario
    Internal Report No. 583
    Internal Report No. 583
    October 1989
    56 p.

  • Lie, T. T.; Irwin, R. J.
    view article (1.0)

    Evaluation of the Fire Resistance of Reinforced Concrete Columns With Rectangular Cross-Section.
    National Research Council of Canada, Ottawa, Ontario
    Internal Report No. 601
    Internal Report No. 601
    October 1989
    79 p.

  • Lie, T. T.; Chabot, M.
    view article (1.0)

    Experimental Studies on the Fire Resistance of Hollow Steel Columns Filled With Plain Concrete.
    National Research Council of Canada, Ottawa, Ontario
    Internal Report No. 611
    Internal Report No. 611
    January 1992
    261 p.

  • Lie, T. T.; Irwin, R. J.; Chabot, M.
    view article (1.0)

    Factors Affecting the Fire Resistance of Circular Hollow Steel Columns Filled With Plain Concrete.
    National Research Council of Canada, Ottawa, Ontario
    Internal Report No. 612
    Internal Report No. 612
    August 1991
    40 p.

  • Chabot, M.; Lie, T. T.
    view article (1.0)

    Experimental Studies on the Fire Resistance of Hollow Steel Columns Filled With Bar-Reinforced Concrete.
    National Research Council of Canada, Ottawa, Ontario
    Internal Report No. 628
    Internal Report No. 628
    April 1992
    47 p.

  • Lie, T. T.; Irwin, R. J.
    view article (1.0)

    Fire Resistance of Rectangular Hollow Steel Sections Filled With Bar-Reinforced Concrete.
    National Research Council of Canada, Ottawa, Ontario
    Internal Report No. 631
    Internal Report No. 631
    July 1992
    38 p.

  • Lie, T. T.; Dawod, I.
    view article (1.0)

    Factors Affecting the Fire Resistance of Square Hollow Steel Columns Filled With Plain Concrete.
    National Research Council of Canada, Ottawa, Ontario
    Internal Report No. 633
    Internal Report No. 633
    August 1992
    38 p.

  • Odeen, K.
    view article (1.0)

    Fire Resistance of Glued, Laminated Timber Structures.
    National Institute for Materials Testing, Stockholm, Sweden
    Paper 2
    Paper 2
    Fire Research Station. Fire and Structural Use of Timber in Buildings. Symposium No. 3. October 25, 1967, Borehamwood, England, 7-15 p., 1967

  • Malhotra, H. L.; Rogowski, B. F. W.
    view article (1.0)

    Fire-Resistance of Laminated Timber Columns.
    Fire Research Station, Borehamwood, England
    Paper 3
    Paper 3