Bankston, C. P.; Powell, E. A.; Cassanova, R. A.; Zinn, B. T.
view article (6.965646)
Detailed Measurements of the Physical Characteristics of Smoke Particulates Generated by Flaming Materials.
Georgia Institute of Technology, Atlanta
Journal of Fire and Flammability,
Vol. 8,
395-411,
1977
Paper 37,
Combustion Institute/Eastern States Section. Chemical and Physical Processes in Combustion. Fall Technical Meeting, 1976. November 18-19, 1976,
Philadelphia, PA,
1-9 p.,
['1976', '1977']
Einhorn, I. N.; Ramakrishnan, M. S.; Mickelson, R. W.
view article (6.965646)
Thermal Degradation of Model Fire-Retarded Urethane Foams: An Analytical Study. Part 2.
Utah Univ., Salt Lake City
FRC/UU-073; UTEC 76-228,
September 24, 1976,
74 p.
Society of the Plastics Industry, Cellular Plastics Division. Cellular Plastics Conference, 4th International. November 18, 1976,
Montreal, Canada,
1976
Zeshang, W.; Wenxin, X.; Weiliang, Z.
view article (6.965646)
Study of Fire Retardant Phenolic Foam.
East China Institute of Technology, Nanjing, China
China Ordnance Society. International Symposium on Flame Retardants Proceedings. November 1-5, 1989,
International Academic Publishers,
Beijing, China,
Yuxiang, O. and Minxiu, Z., Editors,
572-577 p.,
1989
Babrauskas, V.; Harris, R. H., Jr.; Braun, E.; Levin, B. C.; Paabo, M.; Gann, R. G.
view article (6.965646)
Large-Scale Validation of Bench-Scale Fire Toxicity Tests.
National Institute of Standards and Technology, Gaithersburg, MD
Journal of Fire Sciences,
Vol. 9,
No. 2,
125-148,
March/April 1991
Interscience Communications Ltd.; National Institute of Standards and Technology; Building Research Establishment; and Society of Fire Protection Engineers. Interflam 1990. (Interflam '90). Fire Safety. International Fire Conference, 5th. September 3-6, 1990,
Interscience Communications Ltd., London, England,
Canterbury, England,
Franks, C. A., Editors,
3-12 p.,
['1990', '1991']
Backus, J. K.; Darr, W. C.; Gemeinhardt, P. G.; Saunders, J. H.
view article (6.965646)
Thermal Decomposition of Rigid Urethane Foams.
Mobay Chemical Co., Pittsburgh, PA
Journal of Cellular Plastics,
Vol. 1,
No. 1,
178-186,
January 1965
Babrauskas, V.; Harris, R. H., Jr.; Braun, E.; Levin, B. C.; Paabo, M.; Gann, R. G.
view article (6.965646)
Role of Bench-Scale Test Data in Assessing Real-Scale Fire Toxicity.
National Institute of Standards and Technology, Gaithersburg, MD
NIST TN 1284,
January 1991,
110 p.
Ball, G. W.; Ball, L. S.; Walker, M. G.; Wilson, W. J.
view article (6.965646)
Fire Test Data for Urethane-Based and Isocyanurate-Based Rigid Cellular Plastics.
Imperial Chemical Industries Ltd., Manchester, England
Plastics and Polymers,
290-303,
October 1972
Pitts, J. J.; Fuzesi, S.; Andrews, W. R.
view article (6.965646)
Trichlorobutylene Oxide Based Flame Retardant Rigid Polyurethane Foam.
Olin Corp., New Haven, CT
Journal of Cellular Plastics,
Vol. 8,
No. 5,
274-282,
September/October 1972
Green, J.; Versnel, J.
view article (6.965646)
Flame Retarding Plastics With Halogen-Containing Compounds.
Cities Service Co., Cranbury, NJ
JFF/Fire Retardant Chemistry,
Vol. 1,
185-203,
November 1974
Stull, D. P.; Fogerty, R.; Chen, S. M.
view article (6.965646)
Chlorendic Diol-Antimony Trioxide Synergism: Use and Performance of a Novel Rigid Urethane Foam Fire Retardant.
Hauser Labs., Boulder, CO; Velsicol Chemical Corp., Chicago, IL
Journal of Cellular Plastics,
Vol. 22,
No. 3,
147-166,
March 1986