Lin, P.; Lo, S. M.; Huang, H. C.; Yuen, K. K.
view article (6.9967628)
On the Use of Multi-Stage Time-Varying Quickets Time Approach for Optimization of Evacuation Planning.
City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong
Fire Safety Journal,
Vol. 43,
No. 4,
282-290,
May 2008
Ohlemiller, T. J.; Peacock, R. D.
view article (6.9967628)
On the Significance of Transient Heat Release Rate Excursions Above a Set Limit.
National Institute of Standards and Technology, Gaithersburg, MD
Fire Safety Journal,
Vol. 43,
No. 8,
531-540,
November 2008
Steckler, K. D.; Baum, H. R.; Quintiere, J. G.
view article (6.977711)
Salt Water Modeling of Fire Induced Flows in Multicompartment Enclosures.
National Bureau of Standards, Gaithersburg, MD
David Taylor Naval Ship Research and Development Center, Bethesda, MD,
CIB W14/88/13 (USA); NBSIR 86-3327,
March 1986,
52 p.
Combustion Institute Symposium (International) on Combustion, 21st. August 3-8, 1986,
Combustion Inst., Pittsburgh, PA,
Munich, West Germany,
143-150 p.,
1987
Chow, W. K.
view article (6.977711)
On the Evaporation Effect of a Sprinkler Water Spray.
Hong Kong Polytechnic, Kowloon
Fire Technology,
Vol. 25,
No. 4,
364-373,
November 1989
Milke, J. A.
view article (6.977711)
Fire Hazard Assessment in Atriums.
Maryland Univ., College Park
National Fire Protection Association (NFPA). Roundtable on Fire Safety in Atriums--Are the Codes Meeting the Challenge? Technical Papers. December 15-16, 1988,
Washington, DC,
1-46 p.,
1988
Nitta, K.
view article (6.977711)
Calculation Method of Fire-Induced Smoke Flow Through an Opening.
Kyoto Institute of Technology, Japan
HTD-Vol. 141,
American Institute of Aeronautics and Astronautics/American Society of Mechanical Engineers (AIAA/ASME). Heat and Mass Transfer in Fires. AIAA/ASME Thermophysics and Heat Transfer Conference. HTD-Vol. 141. June 18-20, 1990,
Am. Soc. of Mechanical Engineers, New York,
Seattle, WA,
Quintiere, J. G.; Cooper, L. Y., Editors,
77-84 p.,
1990
Bullen, M. L.
view article (6.977711)
Effect of a Sprinkler on the Stability of a Smoke Layer Beneath a Ceiling.
Fire Research Station, Borehamwood, England
FR Note 1016,
July 1974,
16 p.
Milke, J. A.
view article (6.977711)
Author's Response. "Smoke Management for Covered Malls and Atria."
Maryland Univ., College Park
Fire Technology,
Vol. 27,
No. 2,
169-174,
May 1991
Chow, W. K.; Fong, N. K.
view article (6.977711)
Numerical Simulation on Cooling of the Fire-Induced Air Flow by Sprinkler Water Sprays.
Hong Kong Polytechnic, Hung Hom
Fire Safety Journal,
Vol. 17,
No. 4,
263-290,
1991
Maeda, T.; Terai, T.; Yoshida, H.; Sugiura, O.
view article (6.977711)
Measurement of Specific Gravity and Concentration of Smoke.
Kyoto Univ., Japan
Japanese Association of Fire Science and Engineering. Main Reports on Production Movement and Control of Smoke in Buildings. Occasional Report. No. 1. 1974,
92-99 p.,
1974