FireDOC Search

displaying 1821 - 1830 results in total 3737

  • Mawhinney, J. R.; Tamura, G. T.
    view article (1.0)

    Effect of Automatic Sprinkler Protection on Smoke Control Systems.
    National Research Council of Canada, Ottawa, Ontario
    ['94-12-3', 'RP-677']
    ASHRAE Transactions, Vol. 100, No. 1, [pages unknown], 1994
    American Society of Heating, Refrigerating and Air-Conditioning Enginers, Inc., NY; National Fire Laboratory, Canada, 94-12-3; RP-677

  • Hayasaka, H.; Koseki, H.; Tashiro, Y.
    view article (1.0)

    Radiation Measurements in Kerosene Pool Flames Using High-Speed Thermography. [Abstract Only]
    Hokkaido Univ., Sapporo, Japan; Fire Research Institute, Mitaka, Japan
    Report of Fire Research Institute of Japan, No. 74, 14, September 1992

  • Jackson, M. A.; Robins, I.
    view article (1.0)

    Gas Sensing for Fire Detection: Measurements of CO, CO2, H2, O2, and Smoke Density in European Standard Fire Tests.
    Central Research Laboratories, Middlesex, UK
    Fire Safety Journal, Vol. 22, No. 2, 181-205, 1994

  • Matheson, A. F.; Charge, R.
    view article (1.0)

    Comparison of the Fire Behavior of Different Materials in Cable Construction.
    Hydro Polymers Ltd., Aycliffe, UK
    British Plastics Federation AND Institute of Materials. Flame Retardants '94. International Conference, 6th. January 26-27, 1994, Interscience Communications Ltd., London, England, London, England, 73-92 p., 1994

  • Agunloye, F. F.; Stephenson, J. E.; Williams, C. M.
    view article (1.0)

    Improved Intumescent Flame Retardant Systems for Polyolefins.
    Albright and Wilson Ltd., Oldbury, UK
    British Plastics Federation AND Institute of Materials. Flame Retardants '94. International Conference, 6th. January 26-27, 1994, Interscience Communications Ltd., London, England, London, England, 109-116 p., 1994

  • Clemens, M. L.; Doyle, M. D.; Lees, G. C.; Briggs, C. C.; Day, R. C.
    view article (1.0)

    Non-Halogenated Flame Retardant for Polypropylene.
    Manchester Metropolitan Univ., England; Microfine Minerals Limited, England
    British Plastics Federation AND Institute of Materials. Flame Retardants '94. International Conference, 6th. January 26-27, 1994, Interscience Communications Ltd., London, England, London, England, 193-202 p., 1994

  • Olesen, F. B.; Konig, J.
    view article (1.0)

    Tests on Glued Laminated Beams in Bending Exposed to Natural Fires.
    Aalborg Univ., Sweden; Swedish Institute for Wood Technology Research, Stockholm, Sweden

    December 1992
    12 p.
    CIB-W18 Meeting 25. August 1992, Ahus, Sweden, 1992

  • Olesen, F. B.
    view article (1.0)

    Fire Engineering Design of Timber Structures.
    Aalborg Univ., Sweden

    August 1993
    7 p.
    Modern Building Materials, 3rd International Conference. May 1993, Vilnius, Sweden, 1993

  • Koffel, W. E.
    view article (1.0)

    Do Existing Fire Tests Meet Our Needs?
    Koffel Associates, Inc., CT
    NFPA Journal, Vol. 88, No. 2, 14,16, March/April 1994

  • Marlair, G.; Prager, F. H.; Sand, H.
    view article (1.0)

    Behavior of Commercially Important Diisocyanates in Fire Conditions. Part 2. Polymeric Diphenyl Methane-4,4'-diisocyanate (PMDI).
    INERIS, Verneuil-en-Halatte, France; Bayer AG, Leverkusen, Germany; BASF AG, Ludwigshafen, Germany
    Fire and Materials, Vol. 18, No. 1, 17-30, January/February 1994 <b>AND</b> Cellular Polymers, Vol. 12, No. 5, 349-372, 1993,