Daryan, A. S.; Yahai, M.
view article (1.0)
Behavior of Welded Top-Seat Angle Connections Exposed to Fire.
Toosi Univ., Tehran, Iran
Fire Safety Journal,
Vol. 44,
No. 4,
603-611,
May 2009
Chen, X.
view article (1.0)
Flexural Modulus of Symmetric and Asymmetric Structural Foams.
Université Laval, Quebec City, QC, G1K 7P4, Canada
Journal of Cellular Plastics,
Vol. 45,
No. 5,
405-418,
September 2009
Wismans, J. G. F.; VanDommelen, J. A. W.; Govaert, L. E.; Meijer, H. E. H.; VanRietbergen, B.
view article (1.0)
Computed Tomography-based Modeling of Structured Polymers.
Materials Technology Institute Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands
Journal of Cellular Plastics,
Vol. 45,
No. 2,
157-179,
March 2009
Frangi, A.; Fontana, M.; Hugi, E.; Jubsti, R.
view article (1.0)
Experimental Analysis of Cross-Laminated Timber Panels in Fire.
ETH Zurich, Institute of Structural Engineering, 8093 Zurich, Switzerland; Empa, Swiss Laboratories for Materials Testing and Research, 8600 Duebendorf, Switzerland; Graz University of Technology, Institute of Timber Engineering and Wood Technology, 8010 Graz, Austria
Fire Safety Journal,
Vol. 44,
No. 8,
1078-1087,
November 2009
Santiago, A.; Simoes da Silva, L.; Real, P. V.
view article (1.0)
Numerical Modelling of the Influence of Joint Typologies on the 3D Behaviour of a Steel Sub-Frame Under a Natural Fire.
University of Coimbra, Polo II, Pinhal de Marrocos, 3030-290 Coimbra, Portugal; University of Aveiro, Aveiro, Portugal
Fire Technology,
Vol. 46,
No. 1,
49-65,
January 2010
Kandare, E.; Chukwudolue, C.; Kandola, B. K.
view article (1.0)
Use of Fire-Retardant Intumescent Mats for Fire and Heat Protection of Glass Fiber-Reinforced Polyester Composites: Thermal Barrier Properties.
Bolton Univ., UK
Fire and Materials,
Vol. 34,
No. 1,
21-38,
January/February 2010
Wasan, S. R.; Rauwoens, P.; Vierendeels, J.; Merci, B.
view article (1.0)
Application of a Simple Enthalpy-Based Pyrolysis Model in Numerical Simulations of Pyrolysis of Charring Materials.
Ghent University-UGent, Sint-Pietersnieuwstraat-41, B-9000 Ghent, Belgium
Fire and Materials,
Vol. 34,
No. 1,
39-54,
January/February 2010
Zarr, R. R.
view article (1.0)
Assessment of Uncertainties for the NIST 1016 mm Guarded-Hot-Plate Apparatus: Extended Analysis for Low-Density Fibrous-Glass Thermal Insulation.
National Institute of Standards and Technology, Gaithersburg, MD
Journal of Research of the National Institute of Standards and Technology,
Vol. 115,
No. 1,
23-59,
January/February 2010