FireDOC Search

displaying 31 - 40 results in total 92

  • Hawkins, R. L.; Rao, K. N.
    view article (7.6910286)

    Standard Aircraft Diffusion Flame: Spectral Characteristics and a Feasibility Study for Developing an Alternate Calibration Source for Aircraft Optical Fire Detection Systems. Final Report. March 31, 1983-September 30, 1984.
    Ohio State Univ., Columbus, OH
    Aero Propulsion Lab., Wright Patterson AFB, OH, AFWAL-TR-84-2080, December 30, 1984, 23 p.

  • Mountain, R. D.; Mulholland, G. W.
    view article (7.6910286)

    Calibration of Time Response of Thermometers: Concepts and Model Calculations. Final Report.
    National Bureau of Standards, Gaithersburg, MD
    NBS TN 959, January 1978, 34 p.

  • Griffiths, W. D.; Iles, P. J.; Vaughan, N. P.
    view article (7.6910286)

    Behavior of Liquid Droplet Aerosols in an APS 3300.
    Occupational Medicine and Hygiene Labs., London, England
    Journal of Aerosol Science, Vol. 17, No. 6, 921-930, 1986

  • Pitts, W. M.; Lawson, J. R.; Shields, J. R.
    view article (7.6910286)

    NIST/BFRL Calibration System for Heat-Flux Gages. Report of Test 4014.
    National Institute of Standards and Technology, Gaithersburg, MD
    NIST SP 971; FR 4014; Report of Test FR 4014, August 2001; August 6, 2001, 13 p.
    NIST SP 971: "Collected Reports and Publications by the National Institute of Standards and Technology on Heat Flux Gage Calibration and Usage.", 2001

  • Schultz, N.
    view article (7.6910286)

    Practical Application of the Commercial Cone Calorimeter.
    VTEC Laboratories, Inc., Bronx, NY
    Fire Retardant Chemicals Association. Fire Retardant Engineering Polymers and Alloys--Products and Applications--Compounding--Testing and Evaluation. FRCA Spring Conference, 1989. March 12-15, 1989, Technomic Publishing Co., Lancaster, PA, San Antonio, TX, 239-257 p., 1989

  • Lowe, D. L.
    view article (7.6910286)

    Calibration of Accufleet's Heat Flux Gauge (s/n 4615)--Report of Calibration. Letter Report.
    National Institute of Standards and Technology, Gaithersburg, MD
    Letter Report, November 23, 1990, 3 p.

  • Lowe, D. L.
    view article (7.6910286)

    Calibration of Accufleet's Heat Flux Gauge (s/n 4616)--Report of Calibration. Letter Report.
    National Institute of Standards and Technology, Gaithersburg, MD
    Letter Report, November 23, 1990, 3 p.

  • Bulien, O. K.
    view article (7.6910286)

    FTIR Spectrometer for Measuring Toxic Smoke Components in Fire Testing: Review of Equipment and Calibration Routines in NT FIRE 047.
    National Stord/Haugesund College, Norway
    Fire and Materials, Vol. 20, No. 5, 225-233, September/October 1996

  • Thomas, G. C.
    view article (7.6910286)

    Fire Resistance of Light Timber Framed Walls and Floors.
    University of Canterbury, Christchurch, New Zealand
    Fire Engineering Research Report 97/7, May l1997, 324 p.

  • view article (7.6910286)

    Individual's Answers to the Questions. Appendix E.
    NIST/NSF Workshop on Heat Flux Transducers Calibration. Final Report. Proceedings. January 23-24, 1995, Gaithersburg, MD, E/1-41 p., 1995