Fleischmann, C. M.; Parkes, A. R.
view article (6.575887)
Effects of Ventilation on the Compartment Enhanced Mass Loss Rate.
University of Cantebury, Christchurch, NZ; New Zealand Fire Service, Chirstchurch
International Association for Fire Safety Science. Fire Safety Science. Proceedings. Fifth (5th) International Symposium. March 3-7, 1997,
Intl. Assoc. for Fire Safety Science, Boston, MA,
Melbourne, Australia,
Hasemi, Y., Editors,
415-426 p.,
1997
Mawhinney, R. N.; Galea, E. R.; Patel, M. K.
view article (6.575887)
Euler-Lagrange Modelling of Fire/Sprinkler Interactions.
University of Greenwich, London, England
Poster Abstracts,
International Association for Fire Safety Science. Fire Safety Science. Proceedings. Fifth (5th) International Symposium. March 3-7, 1997,
Intl. Assoc. for Fire Safety Science, Boston, MA,
Melbourne, Australia,
Hasemi, Y., Editors,
1336-1336 p.,
1997
Parkes, A. R.
view article (6.575887)
Under-Ventilated Compartment Fires: A Precursor to Smoke Explosions.
University of Canterbury, Christchurch, New Zealand
Fire Engineering Research Report 96/5,
December 1997,
196 p.
Hagglund, B.; Werling, P.; Bengston, S.
view article (6.575887)
Experimental Study of the Effects of Inlet Openings on Natural Fire Ventilation of a Large Compartment.
Defense Research Establishment, Sweden; Brandskyddslaget, Stockholm, Sweden
Journal of Applied Fire Science,
Vol. 7,
No. 1,
73-85,
1997/1998
McGrattan, K. B.; Hamins, A.; Stroup, D. W.
view article (6.575887)
Sprinkler, Smoke and Heat Vent, Draft Curtain Interaction: Large Scale Experiments and Model Development. International Fire Sprinkler-Smoke and Heat Vent-Draft Curtain Fire Test Project.
National Institute of Standards and Technology, Gaithersburg, MD
NISTIR 6196-1,
September 1998,
158 p.
Rimen, J. G.
view article (6.575887)
Assessment of the Use of Positive Pressure Ventilation In an Unpressurised Stairwell.
Home Office Fire Research and Development Group, UK
FRDG Publication Number 11/97,
1997,
109 p.
Consumer Reports
view article (6.575887)
Burning Controversy. Unvented Gas Fireplaces Can Go Almost Anywhere. But Are They Safe?
Consumer Reports,
Vol. 63,
No. 11,
46,
November 1998
Molkov, V. V.
view article (6.575887)
Explosion Safety Engineering: NFPA 68 and Improved Vent Sizing Technology.
All-Russian Research Institute for Fire Protection, Moscow region, Russia
Volume 2,
Interscience Communications Ltd.; National Institute of Standards and Technology; Building Research Establishment; and Society of Fire Protection Engineers; Swedish National Testing and Research Institute. Interflam 1999. (Interflam '99). International Interflam Conference, 8th Proceedings. Volume 2. June 29-July 1, 1999,
Interscience Communications Ltd., London, England,
Edinburgh, Scotland,
1129-1134 p.,
1999
McGrattan, K. B.; Sheppard, D. T,
view article (6.575887)
Large Scale Tests of Sprinkler, Vent, Draft Curtain Interaction.
National Institute of Standards and Technology, Gaithersburg, MD; Underwriters Laboratories, Inc., Northbrook, IL
Interscience Communications Ltd.; National Institute of Standards and Technology; Building Research Establishment; and Society of Fire Protection Engineers; Swedish National Testing and Research Institute. Interflam 1999. (Interflam '99). International Interflam Conference, 8th Proceedings. Volume 1. June 29-July 1, 1999,
Interscience Communications Ltd., London, England,
Edinburgh, Scotland,
685-695 p.,
1999
Galea, E.
view article (6.575887)
Post Graduate Research Projects. Annual Progress Report. Academic Year 1993-1994.
University of Greenwich, London, England
Paper 95/IM/01,
1995,
43 p.