Liu, Z.; Kim, A. K.; Su, J. Z.
view article (7.9896426)
Examination of the Extinguishment Performance of a Water Mist System Using Continuous and Cycling Discharges.
National Research Council of Canada, Ottawa, Ontario
Fire Technology,
Vol. 35,
No. 4,
336-361,
4th Quarter, November 1999
Sheppard, D. T.; Lueptown, R. M.
view article (7.9896426)
Measuring and Calculating Sprinkler Water Distribution.
Bureau of Alcohol, Tobacco and Firearms, Rockville, MD; Northwestern Univ., Evanston, IL
Research and Practice: Bridging the Gap. Fire Suppression and Detection Research Application Symposium. Proceedings. Fire Protection Research Foundation. January 23-25, 2002,
Tampa, FL,
24-32 p.,
2002
Mawhinney, J.
view article (7.9896426)
Mists of Time.
Fire Engineers Journal, Vol. 62, No. 227 / Fire Prevention, No. 363,
29-31,
December 2002
Madrzykowski, D.; Fleming, R. P.
view article (7.9896426)
Residential Sprinkler Systems: Review of Current Data and Technology.
National Institute of Standards and Technology, Gaithersburg, MD; National Fire Sprinkler Association Inc., Patterson, NY
Supplement 3,
Automatic Sprinkler Systems for Residentail Occupancies Handbook. 2nd Edition. Supplement 3,
National Fire Protection Association, Quincy, MA,
Lake, J. D., Editors,
271-292 p.,
2010
American Insurance Association
view article (7.9775925)
Water Supplies--Fire Flow Tests.
American Insurance Assoc., New York
Special Interest Bulletin 42,
September 1975,
2 p.
Lee, B. M.
view article (7.9775925)
New Developments in Fixed Systems.
Wormald International Pty., Ltd., Australia
Fire Engineers Journal,
Vol. 38,
No. 111,
11-14,
September 1978
Schatz, H.
view article (7.9775925)
Loscheinsatz bei gelagerten Stoffen. Teil 12. Literaturauswertung, Messung derWasserbeaufschlagung und -verteilung, Brand- und Loschversuche mit Sprinklern an Regallagern mit und ohne Zusatz von Quellkorpern zum Loschwasser. [Extinguishmgne Techniques for Stored Materials. Part 12. Evaluation of the Literature and Measurements of Water Impact and Water Distribution in Fire and Extinguishment Tests With Sprinklers on Multistory Storage Houses With and Without an Admixture of Swelling Materials in the Extinguishing Water.]
Karlsruhe Univ., West Germany
Report 97; FA. NR. 152,
February 1996,
67 p.
National Interagency Fire Center
view article (7.9775925)
Planning for Water Supply and Distribution in the Wildland/Urban Interface. Operation Water.
National Interagency Fire Center, Boise, ID
National Wildland/Urban Interface,
[date unknonw],
39 p.
Sheppard, D. T.; Gandhi, P. D.; Lueptow, R. M.
view article (7.9775925)
Predicting Sprinkler Water Distribution Using Particle Image Velocimetry.
Underwriters Laboratories, Inc., Northbrook, IL; Northwestern Univ., Evanston, IL
Research and Practice: Bridging the Gap. Fire Suppression and Detection Research Application Symposium. Proceedings. Fire Protection Research Foundation. February 23-25, 2000,
Orlando, FL,
354-364 p.,
2000
Sheppard, D. T.; Gandhi, P. D.; Lueptow, R. M.
view article (7.9775925)
Understanding Sprinkler Sprays: Trajectory Analysis.
Underwriters Laboratories, Inc., Northbrook, IL; Northwestern Univ., Evanston, IL
National Institute of Standards and Technology, Gaithersburg, MD,
NISTIR 6588,
November 2000,
U.S./Japan Government Cooperative Program on Natural Resources (UJNR). Fire Research and Safety. 15th Joint Panel Meeting. Volume 1. Proceedings. March 1-7, 2000,
San Antonio, TX,
Bryner, S. L., Editors,
281-288 p.,
2000