FireDOC Search

displaying 41 - 50 results in total 534

  • Vaari, J.
    view article (6.110931)

    Transient One-Zone Computer Model for Total Flooding Water Mist Fire Suppression in Ventilated Enclosures.
    VTT-Technical Research Center of Finland, Espoo
    Fire Safety Journal, Vol. 37, No. 3, 229-257, April 2002

  • Yang, W.; Kee, R. J.
    view article (6.110931)

    Effect of Monodispersed Water Mists on the Structure, Burning Velocity, and Extinction Behavior of Freely Propagating, Stoichiometric, Premixed, Methane-Air Flames.
    Colorado School of Mines, Golden, CO
    Combustion and Flame, Vol. 130, No. 4, 322-335, September 2002

  • Coffman, L. B., III; Bader, J.
    view article (6.110931)

    Positive Pressure Ventilation: An Emergency Ventilation Technique for Highway, Rail and Subway Tunnel Fires.
    Tempest Technology Corp., USA; Mobile Ventilation Technologies LLC
    Tunnel Fires and Escape From Tunnels, 3rd International Conference. Organised and Sponsored by Tunnel Management International. Proceedings. October 9-11, 2001, Washington, DC, 289-297 p., 2001

  • DeSipio, P. A.
    view article (6.110931)

    Evaluation of Fine Water Mist for Aircraft Dry Bay Fire Suppression.
    Naval Air Warfare Center, Warminster, PA
    Halon Options Technical Working Conference. Proceedings. HOTWC 1996. Sponsored by: University of New Mexico, Halon Alternative Research Corp., National Association of Fire Equipment Distributors, Inc., Hughes Associates, Inc., and Kidde International. May 7-9, 1996, Albuquerque, NM, 27-35 p., 1996

  • Andersson, S.
    view article (6.110931)

    Swedish Phasing Out of Halon for Fire Fighting.
    SP Swedish National Testing and Research Institute, Boras, Sweden
    Halon Options Technical Working Conference. Proceedings. HOTWC 1996. Sponsored by: University of New Mexico, Halon Alternative Research Corp., National Association of Fire Equipment Distributors, Inc., Hughes Associates, Inc., and Kidde International. May 7-9, 1996, Albuquerque, NM, 189-194 p., 1996

  • Williams, C.
    view article (6.110931)

    Recent Research Projects on Automatic Sprinkler Systems and Standards in the UK.
    Building Research Establishment, Garston, England
    Science, Technology and Standards for Fire Suppression Systems. National Research Institute of Fire and Disaster (NRIFD) Symposium, 2nd Proceedings. July 17-19, 2002, Tokyo, Japan, 335-342 p., 2002

  • Vaari, J.
    view article (6.110931)

    European Test Protocol for Total Flooding Water Mist Systems: a Handshake Between Theory and Practice.
    VTT-Technical Research Center of Finland, Espoo
    Science, Technology and Standards for Fire Suppression Systems. National Research Institute of Fire and Disaster (NRIFD) Symposium, 2nd Proceedings. July 17-19, 2002, Tokyo, Japan, 397-410 p., 2002

  • Saso, Y.
    view article (6.110931)

    Questionnaire Data.
    National Research Institute of Fire and Disaster, Tokyo, Japan
    Science, Technology and Standards for Fire Suppression Systems. National Research Institute of Fire and Disaster (NRIFD) Symposium, 2nd Proceedings. July 17-19, 2002, Tokyo, Japan, 471-483 p., 2002

  • Vaari, J.
    view article (6.110931)

    New Performance Evaluation Methodology Opens Up a Door for Ineffective Water Mist Systems.
    VTT-Technical Research Center of Finland, Espoo
    International Fire Protection (IFP) Magazine Magazine, No. 14, 10, May 2003

  • Novozhilov, V.
    view article (6.110931)

    Fundamentals and Application of Fire Suppression Modeling.
    Nanyang Technological Univ., Singapore
    Science, Technology and Standards for Fire Suppression Systems. National Research Institute of Fire and Disaster (NRIFD) Symposium, 2nd Proceedings. July 17-19, 2002, Tokyo, Japan, 195-214 p., 2002