FireDOC Search

displaying 711 - 720 results in total 737

  • Takahashi, F.; Linteris, G. T.; Katta, V. R.
    view article (1.0)

    Extinguishment Mechanisms of Coflow Diffusion Flames in a Cup-Burner Apparatus.
    NASA John H. Glenn Research Center at Lewis Field, Cleveland, OH; National Institute of Standards and Technology, Gaithersburg, MD; Innovative Scientific Solutions Inc., Dayton, OH
    National Aeronautics and Space Administration, Washington, DC, Volume 31; Part 2,
    Combustion Institute, Symposium (International) on Combustion, 31st. Proceedings. Volume 31. Part 2. August 5-11, 2006, Combustion Institute, Pittsburgh, PA, Heidelberg, Germany, Barlow, R. S.; Sick, V.; Glarborg, P.; Yetter, R. A., Editors, 2721-2729 p., 2007

  • Hillebrand, M.
    view article (1.0)

    Fire Suppression Systems.
    Consulting-Specifying Engineer, Vol. 41, No. 1, July 2007

  • Goransson, U.; Husted, B.
    view article (1.0)

    Can Water Mist Be Used to Extinguish Deep-Seated Cellulose Fiber Smoldering Fires? Experiments and Calculations.
    Lund Univ., Sweden; Danish Institute for Fire and Security Technology, Denmark
    Volume 1,
    Interflam 2007. (Interflam '07). International Interflam Conference, 11th Proceedings. Volume 1. September 3-5, 2007, London, England, 359-364 p., 2007

  • Lin, S.; Chuanping, H.; Xinggui, Q.
    view article (1.0)

    Research on Numerical Simulation Comparing With Experments for Water Mist Fire-Extinguishing Process of Oil Pan Fire in Large Space.
    Shanghai Fire Research Institute
    Volume 1; Poster Session,
    Interflam 2007. (Interflam '07). International Interflam Conference, 11th Proceedings. Volume 1. September 3-5, 2007, London, England, 689-694 p., 2007

  • Ponticq, X.; Brousse, B.
    view article (1.0)

    Safety Approach for Fixed Fire-Fighting Systems in Road Tunnels.
    Centre d'Etudes des Tunnels, France
    Volume 2,
    Interflam 2007. (Interflam '07). International Interflam Conference, 11th Proceedings. Volume 2. September 3-5, 2007, London, England, 1693-1698 p., 2007

  • Coleman, R. J.
    view article (1.0)

    AHJ Perspective Stand by to Stand.
    Sprinkler Age, Vol. 26, No. 11, 40-44, November 2007

  • Spadafora, R. R.
    view article (1.0)

    Halon Replacement: Water Mist Fire Extinguishing Systems.
    New York City Fire Dept., NY
    Fire Engineering, Vol. 161, No. 1, 69-70,72,74,76,78,80,82, January 2008

  • Markley, R.
    view article (1.0)

    Ready, Aim, Fire.
    Fire Chief, Vol. 52, No. 1, 82,84,86, January 2008

  • O'Brien, T.
    view article (1.0)

    Fire Sprinklers Need Water.
    VeriFire Limited, Auckland, New Zealand
    Build, 53-54, February/March 2008

  • Priestly, C.
    view article (1.0)

    Gaseous Extinguishing Systems: Relieving the Pressure.
    Fire Safety Engineering, Vol. 15, No. 2, 24-26, March 2008