FireDOC Search

Author
Chen, P. H. | Chuang, Y. J. | Chuang, Y. H. | Lin, C. Y. | Huang, C. H.
Title
Full-Scale Fire Tests to Study Fire Behaviors of Elevator Landing Doors.
Coporate
Kao Yuan Univ., Taiwan National Taiwan University of Science and Technology Nanya Institute of Technology, Taiwan
Journal
Journal of Applied Fire Science, Vol. 15, No. 4, 309-328, 2006-2007
Keywords
elevators (lifts) | doors | large scale fire tests | fire behavior | test methods | experiments | thermocouples | scenarios | ceilings | room fires | temperature | temperature distribution | compartments | surface temperature | insulation
Identifiers
elevator landing door; two-story-high building using the natural fire test method; exterior of the full-scale test building; floor plan of the fire room; thermocouples arrangement in the vertical shaft of elevator