displaying 1 - 10 results in total 297
Cooper, L. Y.
view article (1.0)Measurement of the Smoke Leakage of Door Assemblies During Standard Fire Exposures. Final Report.National Bureau of Standards, Gaithersburg, MDDepartment of Labor, Washington, DC, NBSIR 80-2004, June 1980, 70 p.Margulis, S. T.
view article (1.0)Building Accessibility in Relation to Door Hardware, Door Users, and Door Use.National Bureau of Standards, Gaithersburg, MDNBSIR 80-2174, January 1981, 54 p.Quintiere, J. G.
view article (1.0)Spread of Fire From a Compartment: A Review.National Bureau of Standards, Gaithersburg, MDASTM STP 685,American Society for Testing Materials. Design of Buildings for Fire Safety. Symposium Sponsored by ASTM Committee E05 on Fire Standards. ASTM STP 685. June 27, 1978, American Society for Testing and Materials, PA, Boston, MA, Smith, E. E.; Harmathy, T. Z., Editors, 139-168 p., 1979Kandola, B. S.
view article (1.0)Comparison of Wind Tunnel Pressure Measurements and Smoke Movement Computer Predictions Inside a Five-Storey Model Building.Edinburgh Univ., ScotlandFire Safety Journal, Vol. 10, No. 3, 229-238, May 1986Nakaya, I.; Tanaka, T.; Yoshida, M.; Steckler, K. D.
view article (1.0)Doorway Flow Induced by a Propane Fire.Building Research Institute, Ibaraki, Japan; National Bureau of Standards, Gaithersburg, MDFire Safety Journal, Vol. 10, No. 3, 185-195, May 1986Sugawa, O.; Ogahara, I.; Ozaki, K.; Sato, H.; Hasegawa, I.
view article (1.0)Full Scale Test of Smoke Leakage From Doors of a Highrise Apartment.Science Univ. of Tokyo, Chiba, Japan; Mitsui Fudousan Co., Ltd., Tokyo, Japan; Kajima Corp., Tokyo, Japan; Mitsui Construction Co., Ltd., Chiba, JapanInternational Association for Fire Safety Science. Fire Safety Science. Proceedings. 1st International Symposium. Gaithersburg, MD. Hemisphere Publishing Corp., NY. Grant, C. E. and Pagni, P. J., Editors. 1986. 891-900 pgs. October 7-11, 1985 AND UJNR Panel on Fire Research and Safety. 8th Joint Panel Meeting. Tsukuba, Japan. 927-954 pgs. May 13-21, 1985, 1986Bryan, J. L.; Milke, J. A.
view article (1.0)Determination of Behavior Response Patterns in Fire Situations, Project People II. Final Report. Health Care.Maryland Univ., College ParkNational Bureau of Standards, Gaithersburg, MD, NBS GCR 81-343, October 1981, 304 p.Berhinig, R. M.
view article (1.0)Measurement of Air Flow Around Doors Under Standardizd Fire Test Conditions. June 1978-January 1979.Underwriters Labs., Inc., Northbrook, ILNational Bureau of Standards, Gaithersburg, MD, NBS GCR 81-330, July 1981, 40 p.Bryan, J. L.; Milke, J. A.; DiNenno, P. J.
view article (1.0)Examination and Analysis of the Dynamics of the Human Behavior in the Fire Incident at Thurston Hall on April 19, 1979. Final Report.Maryland Univ., College ParkNational Bureau of Standards, Gaithersburg, MD; Department of Health, Education and Welfare, Washington, DC, NBS GCR 80-193, July 31, 1979, 41 p.Bryan, J. L.; DiNenno, P. J.
view article (1.0)Examination and Analysis of the Dynamics of the Human Behavior in the Fire Incident at the University Nursing Home on April 13, 1979. Final Report.Maryland Univ., College ParkNational Bureau of Standards, Gaithersburg, MD; Department of Health, Education and Welfare, Washington, DC, NBS GCR 80-191, January 1980, 36 p.