FireDOC Search

Author
Mulroy, W. J.
Title
Effect of Short Cycling and Fan Delay on the Efficiency of a Modified Residential Heat Pump.
Coporate
National Bureau of Standards, Gaithersburg, MD
Journal
ASHRAE (American Society of Heating, Refrigeration and Air-Conditioning Engineers) Transactions, Vol. 92, No. Part 1, January 1986
Report
SF-86-17,
Keywords
heat pumps | air conditioning | fans | valvs | test facilities | data analysis
Identifiers
cycling controller; residential air conditioner or heat pump; summarized steady-state data and CD values
Abstract
The object of this study was to detennine if the use of a cycling controller would improve the efficiency of a residential air conditioner or heat pump. Cyclic tests were perfonned on a capillary tube heat pump in three configurations: as manufactured, as modified to simulate a non-bleed expansion valve unit by operation of a valve in the liquid line, and as modified to simulate an air conditioner by elimination of the accumulator. The two modifications, the liquid line valve installation and accumulator removal, were found to greatly improve the cyclic perfonnance to about equal levels; however, some cyclic losses remained. It was concluded that any control strategy that resulted in shortened on-cycle run times would reduce cyclic efficiency for all designs tested. It was further concluded, based in part on the work of others, that fan delay is an undesirable control strategy for units that have the indoor air handler and coil installed within the conditioned space.