FireDOC Search

Author
Kloos, E. J. | Raymond, L. D. | Spinetti, L.
Title
Performance of Open-Circuit Self-Contained Breathing Apparatus at -25 deg F.
Coporate
Bureau of Mines, Pittsburgh, PA
Report
RI 7077, February 1968, 19 p.
Keywords
self contained breathing apparatus | respirators | compressed air | air flow | tests
Abstract
Bureau of Mines-approved self-contained breathing apparatus of the compressed air demand type were evaluated for performance at low temperature. Apparatus durations, breathing resistances, and airflow rates were measured on machine tests at rom temperature and -25 deg F. Man tests under actual wearing conditions verified the machine test results. Many serious functional changes in apparatus performance occurred at low temperature. pressure regulators malfunctioned when diaphragms lost flexibility. Under certain conditions frozen condensed moisture sealed exhalation valves and fogged eyepieces. High-pressure leaks, not encountered at ordinary temperature, developed at low temperature. Tests results are discussed generally and specifically for each apparatus. Recommendations are given to obtain optimum performance from demand type breathing apparatus at low temperatures.