- Author
- Entine, G. | Farrell, R. | Wilson, F. | Wald, F.
- Title
- Infrared Detectors. Final Report. February 28, 1972-September 19, 1973.
- Coporate
- Tyco Laboratories, Inc., Waltham, MA
- Sponsor
- Air Force Systems Command, Wright-Patterson AFB, OH
- Report
- AFAPL-TR-73-104; C-222, November 1973, 73 p.
- Distribution
- Available from National Technical Information Service
- Keywords
- infrared detectors | aircraft engines | fire detectors | flight tests
- Abstract
- CdTe photodectors capable of operating continuously at 75o deg F were packaged for flight testing as an aircraft engine fire detector. The sensors at temperature could detect a photosignal of 50 mu W/cm(2) with a signal-to-noise ratio of over 20:1 and an output impedance of 1000 omega. The units consist of two CdTe sensors separately sealed in hermetic TO-8 headers which are mounted inside a larger hermetically sealed housing made of inconel. The detectors meet MIL-Spec 810B including temperature cycling up to 750 deg F, well above the capability of all the available semiconductor infrared detectors.