FireDOC Search

displaying 1 - 10 results in total 13

  • Burch, D. M.; Licitra, B. A.; Ebberts, D. F.; Zarr, R. R.
    view article (10.004545)

    Thermal Resistance Measurements and Calculations of an Insulated Concrete Block Wall. Final Report.
    National Bureau of Standards, Gaithersburg, MD; Department of Energy, Washington, DC
    ASHRAE Transactions, Vol. 96, No. Part 1, 395-404, 1989

  • Burch, D. M.; Walton, G. N.; Cavanaugh, K.; Licitra, B. A.
    view article (9.588148)

    Effect of Wall Mass on the Annual Heating and Cooling Loads of Single-Family Residences for Five Selected Climates.
    National Bureau of Standards, Gaithersburg, MD
    American Society for Testing and Materials. Thermal Insulation: Materials and Systems. ASTM STP 922. 1987, ASTM, Philadelphia, PA, Philadelphia, PA, Powell, F. J.; Matthews, S. L., Editors, 541-566 p., 1987

  • Burch, D. M.; Licitra, B. A.
    view article (9.588148)

    Effect of Wall Mass on the Annual Space Heating and Cooling Loads of Residences.
    National Bureau of Standards, Gaithersburg, MD
    Proceedings of International Congress of Building Energy Management (3rd), ICBEM '87, September 28-October 2, 1987, Lausanne, Switzerland, 248-255 p., 1987

  • Burch, D. M.; Licitra, B. A.; Zarr, R. R.
    view article (9.580606)

    Comparison of Two Test Methods for Determining Transfer Function Coefficients for a Wall Using a Calibrated Hot Box.
    National Institute of Standards and Technology, Gaithersburg, MD
    Journal of Heat Transfer, Vol. 112, 35-42, February 1990

  • Burch, D. M.; Walton, G. N.; Licitra, B. A.; Cavanaugh, K.
    view article (9.580606)

    Comparison of Measured and Predicted Sensible Heating and Cooling Loads for Six Test Buildings.
    National Bureau of Standards, Gaithersburg, MD
    Electric Power Research Inst., Palo Alto, CA, NBSIR 86-3399, June 1986,

  • Burch, D. M.; Zarr, R. R.; Licitra, B. A.
    view article (9.30499)

    Method for Characterizing the Dynamic Performance of Wall Specimens Using a Calibrated Hot Box.
    National Institute of Standards and Technology, Gaithersburg, MD
    ASHRAE Transactions, Vol. 94, No. Part 1, 125-140, 1988
    No. 3119,

  • Burch, D. M.; Zarr, R. R.; Faison, T. K.; Licitra, B. A.; Arnold, C. E.
    view article (9.30499)

    Procedure for Measuring the Dynamic Thermal Performance of Wall Specimens Using a Calibrated Hot Box.
    National Bureau of Standards, Gaithersburg, MD; Department of Energy, Washington, DC
    ASHRAE (American Society of Heating, Refrigeration and Air-Conditioning Engineers) Transactions, Vol. 93, No. Part 2, 105-119, 1987
    No. 3060,

  • Burch, D. M.; Walton, G. N.; Licitra, B. A.; Cavanaugh, K.; Klein, M. D.
    view article (9.30499)

    Effect of Wall Mass on the Peak Sensible Heating and Cooling Loads of a Single-Family Residence.
    National Bureau of Standards, Gaithersburg, MD; Electric Power Research Inst., Palo Alto, CA
    NBSIR 86-3458, October 1986, 32 p.

  • Zarr, R. R.; Licitra, B. A.
    view article (8.893883)

    Calibration at 24°C of a Heat-Flow-Meter Apparatus Having 610 mm Square Plates.
    National Institute of Standards and Technology, Gaithersburg, MD
    Department of Energy, Washington, DC, NISTIR 4539, May 1991, 35 p.

  • Burch, D. M.; Seem, J. E.; Walton, G. N.; Licitra, B. A.
    view article (8.893883)

    Dynamic Evaluation of Thermal Bridges in a Typical Office Building.
    National Institute of Standards and Technology, Gaithersburg, MD; Johnson Controls Inc., Milwaukee, WI
    ASHRAE Transactions, Vol. 98, No. Part 1, 291-304, 1992
    Paper 3573,