FireDOC Search

displaying 111 - 120 results in total 136

  • SP Swedish National Testing and Research Institute
    view article (1.0)

    BrandPosten, No. 26, June 2002.
    SP Swedish National Testing and Research Institute, Boras, Sweden
    BrandPosten, No. 26, 1-27, June 2002

  • Beer, T.; Williams, A.
    view article (1.0)

    Estimating Australian Forest FireDanger Under Conditions of Doubled Carbon Dioxide Concentrations.
    Commonwealth Scientific and Industrial Research Organization, Melbourne, Australia; Monash Univ., Clayton, Australia
    Climatic Change, Vol. 29, No. 2, 169-188, 1995

  • Alpert, R. L.; Orloff, L.; deRis, J. L.
    view article (1.0)

    Angular Sensitivity of Heat Flux Gages.
    Factory Mutual Research, Norwood, MA
    ['ASTM STP 1427', 'ASTM Stock Number: STP 1427']
    ASTM STP 1427; ASTM Stock Number: STP 1427
    Thermal Measurements: The Foundation of Fire Standards. American Society for Testing and Materials (ASTM). Proceedings. ASTM STP 1427. December 3, 2001, American Society for Testing and Materials, West, Dallas, TX, Gritzo, L. A.; Alvares, N. J., Editors, 67-80 p., 2003

  • Blanchat, T.; Humphries, L.; Gill, W.
    view article (1.0)

    Sandia Heat Flux Gauge Thermal Response and Uncertainty Models.
    Sandia National Laboratories, Albuquerque, NM
    ['ASTM STP 1427', 'ASTM Stock Number: STP 1427']
    ASTM STP 1427; ASTM Stock Number: STP 1427
    Thermal Measurements: The Foundation of Fire Standards. American Society for Testing and Materials (ASTM). Proceedings. ASTM STP 1427. December 3, 2001, American Society for Testing and Materials, West, Dallas, TX, Gritzo, L. A.; Alvares, N. J., Editors, 81-110 p., 2003

  • Wickstrom, U.; Wetterlund, I.
    view article (1.0)

    Total Heat Flux Cannot Be Measured.
    SP Swedish National Testing and Research Institute, Boras, Sweden
    Volume 1
    Volume 1
    Interflam 2004. (Interflam '04). International Interflam Conference, 10th Proceedings. Volume 1. July 5-7, 2004. Organised by Interscience Communications Ltd. in association with National Institute of Standards and Technology, Building Research Establishment; National Fire Protection Association; Society of Fire Protection Engineers; and Swedish National Testing and Research Institute, Interscience Communications Ltd., London, England, Edinburgh, Scotland, 269-276 p., 2004

  • Pitts, W. M.; Murthy, A. V.; deRis, J. L.; Filtz, J. R.; Nygard, K.; Smith, D.; Wetterlund, I.
    view article (1.0)

    Round Robin Study of Total Heat Flux Gauge Calibration at Fire Laboratories.
    National Institute of Standards and Technology, Gaithersburg, MD; Aero-Tech, Inc.,Hampton, VA; FM Global Research, Norwood, MA; LNE: French National Metrology and Testing Laboratory, Trappes, France; SINTEF, Trondheim, Norway; Building Research Establishment, Garston, England; SP Swedish National Testing and Research Institute, Boras, Sweden
    ['NIST SP 1031', 'NIST Special Publication 1031']
    NIST SP 1031; NIST Special Publication 1031
    October 2004
    37 p.

  • Schein, J.; House, J. M.
    view article (1.0)

    Application of Control Charts for Detecting Faults in Variable-Air-Volume Boxes.
    National Institute of Standards and Technology, Gaithersburg, MD; Iowa Energy Center, Ankeny, IA
    KC-03-8-1
    ASHRAE Transactions, Vol. 109, No. 2, 2003
    KC-03-8-1
    ASHRAE Annual Meeting 2003, Kansas City, 671-682 p., 2003

  • Hall, J. R., Jr.
    view article (1.0)

    U.S. Home Product Report (Appliances and Equipment Involved in Fires).
    National Fire Protection Association, Quincy, MA

    November 2005
    164 p.

  • Lennon, P. F.; Silcock, G. W. H.
    view article (1.0)

    Preliminary Investigation into the Partitioning of the Convective and Radiative Incident Heat Flux in Real Fires.
    Ulster Univ.; Letterkenny Institute of Technology
    Fire Technology, Vol. 42, No. 2, 109-129, April 2006

  • Pitts, W. M.; Murthy, A.V.; deRis, J. L.; Filtz, J. R.; Nygard, K.; Smith, D.; Wetterlund, I.
    view article (1.0)

    Round Robin Study of Total Heat Flux Gauge Calibration at Fire Laboratories.
    National Institute of Standards and Technology, Gaithersburg, MD; Aero-Tech, Inc., Hampton, VA; FM Global Research, Norwood, MA; LNE: French National Metrology and Testing Laboratory, Cedex, France; SINTEF NBL Norwegian Fire Research Laboratory, NO-7465 Trondheim, Norway; Building Research Establishment, Garston, England; SP Swedish National Testing and Research Institute, Boras, Sweden
    Fire Safety Journal, Vol. 41, No. 6, 459-475, September 2006