King, M. W.; Menzies, R. W.; Soroka, A. J.; Dirks, E.; Chen, R.; Sun, Y.
view article (5.808482)
Evaluating the TPP of Clothing Exposed to Electric Arcs: A Standard Laboratory Test Apparatus.
University of Manitoba, Winnipeg, Canada; E. I. du Pont de Nemours and Co., Wilmington, DE
ASTM STP 1133,
American Society for Testing and Materials (ASTM). Performance of Protective Clothing: Challenges for Developing Protective Clothing for the 1990s. Fourth (4th) Volume. ASTM STP 1133. June 18-20, 1991,
ASTM, Philadelphia, PA,
Montreal, Canada,
McBriarty, J. P.; Henry, N. W., Editors,
221-236 p.,
1991
Stull, J. O.; Veghte, J. H.; Mann, P. C.; Storment, S. B.
view article (5.808482)
Developing and Selecting Test Methods for Measuring Protective Clothing Performance in Chemical Flashover Situations.
TRI Environmental, Austin, TX; Biotherm, Inc., Beaver Creek, OH; Kappler Safety Group, Guntersville, AL; Phoenix Fire Dept., AZ
ASTM STP 1133,
American Society for Testing and Materials (ASTM). Performance of Protective Clothing: Challenges for Developing Protective Clothing for the 1990s. Fourth (4th) Volume. ASTM STP 1133. June 18-20, 1991,
ASTM, Philadelphia, PA,
Montreal, Canada,
McBriarty, J. P.; Henry, N. W., Editors,
908-923 p.,
1991
Reynolds, T. L.; Porter, K. W.
view article (5.808482)
Aircraft Cabin Water Spray Disbenefits Study. Final Report.
Boeing Commercial Airplane Group, Seattle, WA
National Aeronautics and Space Administration, Hampton, VA; Federal Aviation Administration, Washington, DC,
DOT/FAA/CT-92/6; ACD-240,
October 1993,
148 p.
Petrella, R. V.
view article (5.808482)
Assessment of Full-Scale Fire Hazards and Cone Calorimeter Data.
Flamcon Associates, Midland, MI
Journal of Fire Sciences,
Vol. 12,
No. 1,
14-43,
January/February 1994
Clark, W. E.
view article (5.808482)
Flashover: The Sudden, Silent Killer.
Fire Engineering,
Vol. 147,
No. 6,
26,28-29,
June 1994
Ostman, B. A. L.; Tsantaridis, L. D.
view article (5.808482)
Correlation Between Cone Calorimeter Data and Time to Flashover in the Room Fire Test.
Swedish Institute for Wood Technology Research, Stockholm, Sweden
Fire and Materials,
Vol. 18,
No. 4,
205-209,
July/August 1994
Williamson, R. B.
view article (5.808482)
Fuel Loading and Its Contribution to Hazard in High-Rise Buildings.
California Univ., Berkeley
University of Utah. Fire Prevention and Control: A Major Societal Problem. Polymer Conference Series. June 4-9, 1973,
Salt Lake City, UT,
1-6 p.,
1973
Beard, A. N.; Drysdale, D. D.; Holborn, P.; Bishop, S.
view article (5.808482)
Model of Instability and Flashover.
University of Edinburgh, Scotland; University College, London, England
Journal of Applied Fire Science,
Vol. 4,
No. 1,
3-16,
1994-1995
Dunn, V.
view article (5.808482)
Fire Dangers.
New York City Fire Dept., NY
Firehouse,
Vol. 20,
No. 4,
20,22,112,
April 1995
Moore, P.
view article (5.808482)
Why Fires Go to Blazes.
New Scientist,
Vol. 146,
No. 1980,
26-30,
June 3, 1995