FireDOC Search

displaying 31 - 39 results in total 39

  • Feng, M.; Wang, Y. C.
    view article (1.0)

    Experimental Study of Loaded Full-Scale Cold-Formed Thin-Walled Steel Structural Panels Under Fire Conditions.
    UMIST and University of Manchester, P.O. Box 88, Manchester M60 1QD, UK
    Fire Safety Journal, Vol. 40, No. 1, 43-63, February 2005

  • Collier, P. C. R.
    view article (1.0)

    Post-Earthquake Performance of Passive Fire Protection Systems.
    Building Research Association of New Zealand, Judgeford
    Study Report No. 147; BRANZ Study Report SR 147, 2005, 96 p.

  • Brown, N.
    view article (1.0)

    Steelwork Partially Protected From Post-Flashover Fires In Gypsum Plasterboard Lined Compartments.
    University of Canterbury, Christchurch, New Zealand
    Fire Engineering Research Report 07/3, 2007, 144 p.

  • Collier, P.
    view article (1.0)

    Do Earthquakes Damage Fire Protection Walls?
    Building Research Association of New Zealand, Judgeford
    Build, 84-85, February/March 2008

  • Sultan, M. A.
    view article (1.0)

    Fall-Out of Gypsum Plasterboard in Fire.
    National Research Council of Canada, Ottawa, Ontario
    NRCC-50098,
    Structures in Fire (SiF 2008), 5th International Conference. Proceedings. May 28-30, 2008, Singapore, 644-655 p., 2008

  • Wakili, K. G.; Hugh, E.
    view article (1.0)

    Four Types of Gypsum Plaster Boards and Ttheir Thermophysical Properties Under Fire Condition.
    Empa, Swiss Federal Laboratories for Materials Testing and Research CH-8600 Duebendorf, Switzerland
    Journal of Fire Sciences, Vol. 27, No. 1, 27-43, January 2009

  • Shelley, J.; Spearpoint, M.; Bittern, A.
    view article (1.0)

    Tenability Analysis of Television Set Fires in a Sprinkler Protected Compartment.
    Connell Wagner, Brisbane, Australia; University of Canterbury, Christchurch, New Zealand; WSP, Edinburgh, Scotland
    Journal of Applied Fire Science, Vol. 16, No. 1, 35-70, 2006-2007

  • Frangi, A.; Schleifer, V.; Fontana, M.; Hugi, E.
    view article (1.0)

    Experimental and Numerical Analysis of Gypsum Plasterboards in Fire.
    Institute of Structural Engineering, ETH Zurich, 8093 Zurich, Switzerland; Empa, Swiss Laboratories for Materials Testing and Research, 8600 Duebendorf, Switzerland
    Fire Technology, Vol. 46, No. 1, 149-167, January 2010

  • deKorte, A. C. J.; Brouwers, H. J. H.
    view article (1.0)

    Calculation of Thermal Conductivity of Gypsum Plasterboards at Ambient and Elevated Temperature.
    Twente Univ., Enschede, The Netherlands
    Fire and Materials, Vol. 34, No. 2, 55-75, March 2010