FireDOC Search

displaying 541 - 550 results in total 606

  • Stroup, D. W.; Evans, D. D.
    view article (5.772987)

    Suppression of Post-Flashover Compartment Fires Using Manually Applied Water Sprays.
    National Institute of Standards and Technology, Gaithersburg, MD
    Brandforsk, Stockholm, Sweden; General Services Administration, Washington, DC, NISTIR 4625, July 1991, 40 p.

  • Stroup, D. W.; Madrzykowski, D.
    view article (5.772987)

    Conditions in Corridors and Adjoining Areas Exposed to Post-Flashover Room Fires.
    National Institute of Standards and Technology, Gaithersburg, MD
    General Services Administration, Washington, DC, NISTIR 4678, September 1991, 74 p.

  • Hou, R.; Jian, G. F.; Wang, Q. A.; Hirano, T.
    view article (5.772987)

    Effects of Opening Position on Room Fire Characteristics.
    University of Science and Technology of China, Anhui; Tokyo Univ., Bunkyo-ku
    Bulletin of Japan Association for Fire Science and Engineering, Vol. 40, No. 2, 19-24, 1991

  • Hagglund, B.; Jored, K.
    view article (5.772987)

    Simulating the Smoke Filling in a Two-Compartment Structure.
    National Defence Research Establishment, Sundbyberg, Sweden
    FOA Report C20849-2.4, December 19912, 48 p.

  • Tan, Q.; Jaluria, Y.
    view article (5.772987)

    Flow Through Horizontal Vents as Related to Compartment Fire Environments. September 29, 1990-September 30, 1991.
    Rutgers Univ., New Brunswick, NJ
    National Institute of Standards and Technology, Gaithersburg, MD, NIST GCR 92-607, June 1992, 105 p.

  • Nelson, H. E.; Deal, S.
    view article (5.772987)

    CORRIDOR: A Routine for Estimating the Initial Wave Front Resulting From High Temperature Fire Exposure to a Corridor.
    National Institute of Standards and Technology, Gaithersburg, MD
    General Services Administration, Washington, DC, NISTIR 4869, July 1992, 39 p.

  • Nilsson, P.
    view article (5.772987)

    ADA - Program for berakning av rok-och varmespridning i generella en-rumsmoduler. [ADA - Program for Computing the Spread of Smoke and Heat in General One-Room Modules.]
    National Defence Research Establishment, Sundbyberg, Sweden
    FOA Report C20886-2.4, June 1992, 53 p.

  • Braun, E.; Lowe, D. L.; Jones, W. W.; Tatem, P.; Bailey, J.; Carey, R.
    view article (5.772987)

    Comparison of Full Scale Fire Tests and a Computer Fire Model of Several Smoke Ejection Experiments.
    National Institute of Standards and Technology, Gaithersburg, MD; Naval Research Laboratory, Washington, DC; David Taylor Naval Ship Research and Development Center, Annapolis, MD
    Naval Research Laboratory, Washington, DC, NISTIR 4961, November 1992, 43 p.

  • Gandhi, P. D.
    view article (5.772987)

    Using Calorimeter Data and a Zone Model to Predict Smoke Obscuration in Room Fires: A Parametric Study.
    Underwriters Laboratories, Inc., Northbrook, IL
    Fire Safety Journal, Vol. 20, 115-133, 1993

  • Karlsson, B.; Magnusson, S. E.
    view article (5.772987)

    Room Fire Models. Part B. An Example Room Fire Model.
    Lund Univ., Sweden
    Chapter 6,
    Heat Release in Fires, Elsevier Applied Science, NY, Babrauskas, V.; Grayson, S. J., Editors, 159-171 p., 1992