  • Parnell, A. C.; Butcher, E. G.
    view article (4.417726)

    Smoke Movement in Atria.
    Fire Check Consultants, London, England
    Fire Protection, Vol. 11, No. 3, 4-6, September 1984

  • Hilado, C. J.; Brauer, D. P.
    view article (4.417726)

    Evaluation of Airfield Pavement Materials Based on Synthetic Polymers.
    San Francisco Univ., CA
    Journal of Fire and Flammability, Vol. 10, No. 3, 207-215, July 1979
    International Conference on Fire Safety, 4th. Volume 4. January 15-19, 1979., San Francisco, CA, 94-106 p., 1979

  • Woollerton, G. R.; Culver, D.
    view article (4.417726)

    Small Scale Laboratory Flammability Test for Electronic Components.
    Northern Telecom Canada Ltd., Montreal, Canada; Bell-Northern Research, Ontario, Canada
    Journal of Fire and Flammability, Vol. 12, No. 2, 89-105, April 1980
    International Conference on Fire Safety, 4th. Volume 4. January 15-19, 1979., San Francisco, CA, 188-205 p., 1979

  • Hurd, R.
    view article (4.417726)

    Improvements in the Fire Performance of Rigid Polyurethane Foam.
    ICI Organics Div., Manchester, England
    Development in Polyurethane, Vol. 1, No. Chapter 7, 175-198, 1978

  • Jin, T.; Yamada, T.
    view article (4.417726)

    Emotional Instability in Fire Smoke. Experiment of Human Behavior in Smoke Filled Corridor.
    Fire Research Inst., Tokyo, Japan
    NBSIR 88-3753,
    U.S./Japan Government Cooperative Program on Natural Resources (UJNR). Fire Research and Safety. 9th Joint Panel Meeting of the UJNR Panel. May 4-8, 1987, Norwood, MA, 1-10 p., 1987

  • Crook, J. W.; Hott, P.; Weimer, J. T.; Farrand, R. L.; Cooper, A. E.; Manthel, J. H.; Nelson, R.; Heitkamp, D. H.
    view article (4.417726)

    Acute Toxicity of Polyethylene Clycol 200 in Laboratory Animals. Technical Report. September 1979-December 1980.
    Chemical Systems Lab., Aberdeen Proving Ground, MD
    ARCSL-TR-81058, October 1981, 26 p.

  • Trotter, A. B.; Trotter, K.
    view article (4.417726)

    Dependence of the Early Fire Hazard Smoke Measurement (As 1530 Pt 3) on the Test Conditions and Environment.
    Physics and Engineering Lab., DSIR, Wellington, New Zealand
    Report 714; PEL R-714, June 1981, 15 p.

  • Kaplan, H. L.; Grand, A. F.; Switzer, W. G.; Gad, S. C.
    view article (4.417726)

    Acute Inhalation Toxicity of the Smoke Produced by Five Halogenated Polymers.
    Southwest Research Inst., San Antonio, TX; Allied Corp., Morristown, NJ
    Journal of Fire Sciences, Vol. 2, No. 2, 153-172, March/April 1984

  • Sykes, F.
    view article (4.417726)

    Modelling Smoke Flow in Buildings.
    Leeds School of Architecture
    Fire Prevention, 19-33, January/February 1984

  • Egan, M. R.; Litton, C. D.
    view article (4.417726)

    Wood Crib Fires in a Ventilated Tunnel.
    Bureau of Mines, Pittsburgh, PA
    RI 9045, 1986, 25 p.