Schultz, N.
view article (7.5512667)
Practical Application of the Commercial Cone Calorimeter.
VTEC Laboratories, Inc., Bronx, NY
Fire Retardant Chemicals Association. Fire Retardant Engineering Polymers and Alloys--Products and Applications--Compounding--Testing and Evaluation. FRCA Spring Conference, 1989. March 12-15, 1989,
Technomic Publishing Co., Lancaster, PA,
San Antonio, TX,
239-257 p.,
1989
Tamura, G.
view article (7.5512667)
Smoke Control for High-Rises in Japan.
National Fire Lab., Japan
Fire Research News, No. 63, 1-2, Winter 1992 <b>AND</b> Fire International, No. 134, 31, April/May 1992,
Tamura, G. T.; MacDonald, R. A.
view article (7.5512667)
Comparative Performances of Mechanical Smoke Exhaust System, Zoned Smoke Control, and Pressurized Building Method of Smoke Control.
National Research Council of Canada, Ottawa, Ontario
ASHRAE Transactions: Research,
488-495,
1993
Paper 3670,
Ogle, L. D.; LaCosse, J. P.; Gray, W. C.; Rohlack, L. A.; Shareef, G. S.; Evans, J. M.; McCarthy, J. M.
view article (7.5512667)
Validation of a Fourier Tranform Infrared (FTIR) Method for Measuring Aldehydes in Engine Exhaust.
Radian Corp., Research Triangle Park, NC; Gas Research Inst., Chicago, IL
University of California, Berkeley. Toxic Toxic Combustion Byproducts. 4th International Congress. ABSTRACTS ONLY. June 5-7, 1995,
Berkeley, CA,
122 p.,
1995
Sharry, J. A.
view article (7.5512667)
Atrium Fire.
National Fire Protection Association, Quincy, MA
Fire Journal,
Vol. 67,
No. 6,
39-41,
November 1973
Ferreira, M. J.; White, D. A.; Trelles, J.; Wu, P. W.
view article (7.5512667)
Emergency Smoke Control System Design for Semiconductor Fabrication Facilities: Is Property Protection Achievable?
Hughes Associates, Inc., Baltimore, MD; Industrial Technology Research Institute, Taiwan, R.O.C.
Volume 1,
Interscience Communications Ltd.; National Institute of Standards and Technology; Building Research Establishment; and Society of Fire Protection Engineers; Swedish National Testing and Research Institute. Interflam 1999. (Interflam '99). International Interflam Conference, 8th Proceedings. Volume 1. June 29-July 1, 1999,
Interscience Communications Ltd., London, England,
Edinburgh, Scotland,
429-440 p.,
1999
Chow, W. K.; Li, J. S. M.
view article (7.5512667)
Review on Safety Requirement and Fire Regulations for Tunnels in the Hong Kong Special Administrative Region.
Hong Kong Polytechnic Univ., China
Engineering Performance-Based Fire Codes, 1st International Symposium. Proceedings. Organized and Supported by the Hong Kong Polytechnic University. September 8, 1998,
Hong Kong, China,
Chow, W. K., Editors,
161-170 p.,
1998
Chung, K. C.
view article (7.5512667)
Evaluation of Smoke Exhaustion Performance of a Vestible Within Tall Buildings in Taiwan.
National Yunlin University of Science and Technology, Taiwan
International Journal on Engineering Performance-Based Fire Codes,
Vol. 1,
No. 2,
71-80,
1999
Seem, J. E.; House, J. M.; Kelly, G. E.; Klaassen, C. J.
view article (7.5512667)
Damper Control System for Preventing Reverse Airflow Through the Exhaust Air Damper of Variable-Air-Volume Air-Handling Units.
Johnson Controls, Inc., Milwaukee, WI; National Institute of Standards and Technology, Gaithersburg, MD; Energy Center Energy Resource Station, Ankeny, IA
HVAC&R Research,
Vol. 6,
No. 2,
135-148,
April 2000
Werner, C.
view article (7.5512667)
New Technology in the Firehouse.
Charlottesville Fire Dept., VA
Firehouse,
Vol. 26,
No. 8,
124,126-128,
August 2001