FireDOC Search

displaying 1 - 10 results in total 13

  • Murthy, A. V.; Tsai, B. K.; Saunders, R. D.
    view article (1.0)

    High Heat Flux Sensors Calibration Using Black-Body Radiation.
    Aero-Tech, Inc., Hampton, VA; National Institute of Standards and Technology, Gaithersburg, MD
    Metrologia, Vol. 35, No. 4, 501-504, 1998
    NIST SP 971, August 2001,
    NIST SP 971: "Collected Reports and Publications by the National Institute of Standards and Technology on Heat Flux Gage Calibration and Usage.", ['2001', '1998']

  • Murthy, A. V.; Tsai, B. K.; Saunders, R. D.
    view article (1.0)

    Aperture Proximity Effects in High Heat Flux Sensors Calibration.
    Aero-Tech, Inc., Hampton, VA; National Institute of Standards and Technology, Gaithersburg, MD
    Journal of Research of the National Institute of Standards and Technology, Vol. 103, No. 6, 621-624, November/December 1998
    NIST SP 971, August 2001,
    NIST SP 971: "Collected Reports and Publications by the National Institute of Standards and Technology on Heat Flux Gage Calibration and Usage.", ['2001', '1998']

  • Murthy, A. V.; Tsai, B. K.; Gibson, C. E.
    view article (1.0)

    Calibration of High Heat Flux Sensors at NIST.
    Aero-Tech, Inc., Hampton, VA; National Institute of Standards and Technology, Gaithersburg, MD
    Journal of Research of the National Institute of Standards and Technology, Vol. 102, No. 4, 479-488, July/August 1997
    NIST SP 971, August 2001,
    NIST SP 971: "Collected Reports and Publications by the National Institute of Standards and Technology on Heat Flux Gage Calibration and Usage.", ['2001', '1997']

  • Murthy, A. V.; Tsai, B. K.; Saunders, R. D.
    view article (1.0)

    Comparative Calibration of Heat Flux Sensors in Two Blackbody Facilities.
    Aero-Tech, Inc., Hampton, VA; National Institute of Standards and Technology, Gaithersburg, MD
    Journal of Research of the National Institute of Standards and Technology, Vol. 104, No. 5, 487-494, September/October 1999
    NIST SP 971, August 2001,
    NIST SP 971: "Collected Reports and Publications by the National Institute of Standards and Technology on Heat Flux Gage Calibration and Usage.", ['2001', '1999']

  • Murthy, A. V.; Tsai, B. K.; Saunders, R. D.
    view article (1.0)

    Radiative Calibration of Heat Flux Sensors at NIST: Facilities and Techniques.
    Aero-Tech, Inc., Hampton, VA; National Institute of Standards and Technology, Gaithersburg, MD
    Journal of Research of the National Institute of Standards and Technology, Vol. 105, No. 2, 293-305, March/April 2000
    NIST SP 971, August 2001,
    NIST SP 971: "Collected Reports and Publications by the National Institute of Standards and Technology on Heat Flux Gage Calibration and Usage.", ['2001', '2000']

  • Murthy, A. V.; Tsai, B. K.; Saunders, R. D.
    view article (1.0)

    High Heat Flux Sensors Calibration in a Cooled Enclosure.
    Aero-Tech, Inc., Hampton, VA; National Institute of Standards and Technology, Gaithersburg, MD
    NIST SP 971, August 2001,
    NIST SP 971: "Collected Reports and Publications by the National Institute of Standards and Technology on Heat Flux Gage Calibration and Usage." AND Instrumentation Symposium, 45th International. Proceedings. Sponsored by Aerospace Industries Division and Test Measurement division of ISA. May 2-6, 1999, Albuquerque, NM, 91-100 p., ['2001', '1999']

  • Murthy, A. V.; Tsai, B. K.
    view article (1.0)

    Transfer Calibration of Heat Flux Sensors at NIST.
    Aero-Tech, Inc., Hampton, VA; National Institute of Standards and Technology, Gaithersburg, MD
    NIST SP 971, August 2001,
    NIST SP 971: "Collected Reports and Publications by the National Institute of Standards and Technology on Heat Flux Gage Calibration and Usage." AND National Heat Transfer Conference, 32nd ASME Proceedings. Volume 7. HTD-Vol. 345. American Society of Mechanical Engineers (ASME). 1997, Kaminski, D.; Smith, A. M.; Smith, T. F., Editors, 81-88 p., ['2001', '1997']

  • Murthy, A. V.; Tsai, B. K.; Suanders, R. D.
    view article (1.0)

    Radiative Calibration of Heat Flux Sensors at NIST: An Overview.
    Aero-Tech, Inc., Hampton, VA; National Institute of Standards and Technology, Gaithersburg, MD
    NIST SP 971, August 2001,
    NIST SP 971: "Collected Reports and Publications by the National Institute of Standards and Technology on Heat Flux Gage Calibration and Usage." AND ASME Heat Transfer Proceedings. Volume 3. HTD-Vol. 353. American Society of Mechanical Engineers (ASME). ASME International Mechanical Engineering Congress and Exposition. 1997, 159-164 p., ['2001', '1997']

  • Murthy, A. V.; Wetterlund, I.; DeWitt, D. P.
    view article (1.0)

    Characterization of an Ellipsoidal Radiometer.
    Aero-Tech, Inc., Hampton, VA; SP Swedish National Testing and Research Institute, Boras, Sweden; National Institute of Standards and Technology, Gaithersburg, MD
    Journal of Research of the National Institute of Standards and Technology, Vol. 108, No. 2, 115-124, March/April 2003

  • Murthy, A. V.; Tsai, B. K.; Saunders, R. D.
    view article (1.0)

    Calibration of a Heat Flux Sensor Up to 200 kW/m2 in a Spherical Blackbody Cavity.
    Aero-Tech, Inc., Hampton, VA; National Institute of Standards and Technology, Gaithersburg, MD; Saunders Enterprises, Gaithersburg, MD
    ASTM STP 1427; ASTM Stock Number: STP 1427,
    Thermal Measurements: The Foundation of Fire Standards. American Society for Testing and Materials (ASTM). Proceedings. ASTM STP 1427. December 3, 2001, American Society for Testing and Materials, West, Dallas, TX, Gritzo, L. A.; Alvares, N. J., Editors, 51-66 p., 2003