Khoury, G. A.; Grainger, B. N.; Sullivan, P. J. E.
view article (1.0)Transient Thermal Strain of Concrete: Literature Review, Conditions Within Specimen and Behavior of Individual Constituents. Transient Thermal Strain of Concrete During First Heating Cycle to 600 Deg. C.Imperial College of Science and Technology, London, England; Central Electricity Research Labs., Surrey, EnglandCIB W14/86/45 (UK)Magazine of Concrete Research, Vol. 37, No. 132, 131-144, September 1985CIB W14/86/45 (UK)Khoury, G. A.; Grainger, B. N.; Sullivan, P. J. E.
view article (1.0)Strain of Concrete During First Cooling From 600 Deg. C Under Load. Transient Thermal Strain of Concrete During First Heating Cycle to 600 Deg. C.Imperial College of Science and Technology, London, England; Central Electricity Research Labs., Surrey, EnglandCIB W14/86/45 (UK)Magazine of Concrete Research, Vol. 38, No. 134, 1-12, March 1986CIB W14/86/45 (UK)Sullivan, P. J. E.; Dougill, J. W.
view article (1.0)Developments in Design of Structural Concrete Under Fire Conditions.Imperial College, London, EnglandFire Research Station. International Seminar on Three Decades of Structural Fire Safety. Organized by Bill Malhotra on the Occasion of His Retirement. February 22-23, 1983., Borehamwood, England, 261-277 p., 1983Sullivan, P. J. E.; Khoury, G. A.
view article (1.0)Fire Performance of Various Concretes Deduced From Strain Measurements During First Heating.Imperial CollegeACI SP-92-10ACI SP-92-10Evaluation and Repair of Fire Damage to Concrete, American Concrete Inst., Detroit, MI, Harmathy, T. Z., Editors, 175-196 p., 1986Khoury, G. A.; Sullivan, P. J. E.
view article (1.0)Research at Imperial College on the Effect of Elevated Temperatures on Concrete.London Univ., EnglandFire Safety Journal, Vol. 13, No. 1, 69-72, April 1988European Convention for Construction Steelwork (ECCS). Workshop on Mechanical Properties at Elevated Temperatures. June 12, 1986., Arnhem, The Netherlands, Twilt, L., Editors, 1988Sullivan, P. J. E.
view article (1.0)Structural Design for Fire.Imperial College, London, EnglandConsulting Engineer, Vol. 38, No. 9, 45-47, September 1974Sullivan, P. J. E.; Sharshar, R.
view article (1.0)Performance of Concrete at Elevated Temperatures (As Measured by the Reduction in Compressive Strength).Sullivan and Associates, Richmansworth, England; Imperial College, London, EnglandFire Technology, Vol. 28, No. 3, 240-250, August 1992Sullivan, P. J. E.; Terro, M. J.; Morris, W. A.
view article (1.0)Critical Review of Fire-Dedicated Thermal and Structural Computer Programs.City Univ., London, England; Kuwait Univ.; Fire Research Station, Borehamwood, EnglandJournal of Applied Fire Science, Vol. 3, No. 2, 113-135, 1993/1994Akhtaruzzaman, A. A.; Sullivan, P. J. E.
view article (1.0)Development and Calibration of a Deflection Measuring System Using an Integrated Operational Amplifier Circuit.Imperial College of Science and Technology, London, EnglandCSTR 70/1CSTR 70/1
December 1970
11 p.Akhtaruzzaman, A. A.; Sullivan, P. J. E.
view article (1.0)Explosive Spalling of Concrete Exposed to High Temperature.Imperial College of Science and Technology, London, EnglandCSTR 70/2CSTR 70/2
December 1970
34 p.