displaying 1 - 10 results in total 34
Bryan, J. L.; DiNenno, P. J.
view article (1.0)Examination and Analysis of the Dynamics of the Human Behavior in the Fire Incident at the Magnolia Gardens Nursing Home on April 2, 1978.Maryland Univ., College ParkNBS GCR 80-211National Bureau of Standards, Gaithersburg, MD, NBS GCR 80-211
July 31, 1978
43 p.De Souza, B. P.; Yang, K. T.; Lloyd, J. R.
view article (1.0)Numerical Simulations of the Effect of Floor and Ceiling Venting on Fire and Smoke Spread in Aircraft Cabins.National Bureau of Standards, Gaithersburg, MD['NBS GCR 84-479', 'NBS Grant No. NB81NADA2000']NBS GCR 84-479; NBS Grant No. NB81NADA2000
February 1985
71 p.DeSouza, B. P.; Lloyd, J. R.; Yang, K. T.
view article (1.0)Numerical Simulations of the Effect of Ventilation Control on Fire and Smoke Spread in Aircraft Cabins.Notre Dame Univ., INNational Bureau of Standards, Gaithersburg, MD,
1984
8 p.DeSouza, B. P.; Lloyd, J. R.; Yang, K. T.
view article (1.0)Numerical Simulations of the Effect of Ventilation Control on Fire and Smoke Spread in Aircraft Cabins.Notre Dame Univ., INNational Heat Transfer Conference, 22nd. August 5-8, 1984, Niagara Falls, NY, 1-7 p., 1984Cooper, L. Y.
view article (1.0)Estimating the Environment and the Response of Sprinkler Links in Compartment Fires With Draft Curtains and Fusible Link-Actuated Ceiling Vents. Part 1. Theory.National Bureau of Standards, Gaithersburg, MDNBSIR 88-3734AAMA Research Foundation, Des Plaines, IL, NBSIR 88-3734
April 1988
37 p.Cooper, L. Y.
view article (1.0)Estimating the Environment and the Response of Sprinkler Links in Compartment Fires With Draft Curtains and Fusible Link-Actuated Ceiling Vents: An Overview.National Bureau of Standards, Gaithersburg, MDUS-Japan Conference on Utilization of Natural Resources. 10th Joint Meeting of the UJNR Panel on Fire Research and Safety. June 9-10, 1988, Tsukuba, Japan, 5 pp AND Combustion Institute/Eastern States Section. Chemical and Physical Process in Combustion. 1988 Technical Meeting. December 5-7, 1988, Clearwater Beach, FL, 61/1-4 pp, AND U.S./Japan Government Cooperative Program on Natural Resources (UJNR). Fire Research and Safety. 10th Joint Panel Meeting. June 9-10, 1988, Tsukuba, Japan, 87-91 pp, 1988Cooper, L. Y.
view article (1.0)Calculation of the Flow Through a Horizontal Ceiling/Floor Vent.National Institute of Standards and Technology, Gaithersburg, MDNISTIR 89-4052Naval Research Lab., Washington, DC, NISTIR 89-4052
February 1989
30 p.Davis, W. D.; Cooper, L. Y.
view article (1.0)Estimating the Environment and the Response of Sprinkler Links in Compartment Fires With Draft Curtains and Fusible Link-Actuated Ceiling Vents. Part 2. User Guide for the Computer Code LAVENT.National Institute of Standards and Technology, Gaithersburg, MDNISTIR 89-4122AAMA Research Foundation, Des Plaines, IL, NISTIR 89-4122
August 1989
422 p.Cooper, L. Y.
view article (1.0)Estimating the Environment and the Response of Sprinkler Links in Compartment Fires With Draft Curtains and Fusible Link-Actuated Ceiling Vents: Theory.National Institute of Standards and Technology, Gaithersburg, MDFire Safety Journal, Vol. 16, No. 2, 137-163, 1990AAMA Research Foundation, Des Plaines, IL,Tu, K. M.
view article (1.0)Experimental Study of Top Vented Compartment Fires.National Institute of Standards and Technology, Gaithersburg, MDNISTIR 4499NISTIR 4499
February 1991
33 p.