FireDOC Search

displaying 141 - 150 results in total 374

  • Bradley, M. M.; Molenkamp, C. R.
    view article (1.0)

    Numerical Model of Aerosol Scavenging. Part 2. Simulation of a Large City Fire.
    Lawrence Livermore Lab., CA
    UCRL-JC-106110
    Department of Energy, Washington, DC, UCRL-JC-106110
    October 1991
    15 p.
    International Conference on Precipitation Scavenging and Atmosphere-Surface Exchange Processes, 5th. July 15-19, 1991, Richland, WA, 1991

  • Finnie, M. J.
    view article (1.0)

    Qualification Operational Test and Evaluation (QOT&E) of the C-5 Aircraft Pylon Fire Safety Modification. OperationalTest and Evaluation.
    Military Airlift Command, Scott AFB, IL
    MAC Test Order 5-66-90
    MAC Test Order 5-66-90
    July 1991
    13 p.

  • Bengtson, S.
    view article (1.0)

    Forskningsbehov brandskydd av overglasade gardar. [Technical Overview of Fire Protection in Malls.]
    National Defence Research Establishment, Sundbyberg, Sweden
    Sultrapport 1992 01 20
    Sultrapport 1992 01 20
    1992
    150 p.

  • Klote, J. H.; Milke, J. A.
    view article (1.0)

    Design of Smoke Management Systems.
    National Institute of Standards and Technology, Gaithersburg, MD; Maryland Univ., College Park
    American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc., Atlanta, GA; Society of Fire Protection Engineers, Boston, MA,
    Design of Smoke Management Systems, 236 p., 1992

  • John, R.
    view article (1.0)

    Fire and Extinction Tests With Gaseous Extinguishing Agents in Full-Scale Rooms. Part 2. Determination of Volume Flow Through Doors for Smoke Control on Escape Routes. [Brand- und Loschversuche mit gasformigen Loschmittein in Raumen naturlicher Grosse. Teil 2. Ermittlung der Volumenstorme durch Turoffnungen zur Rauchfreihaltung von Rettungswegen.]
    Karlsruhe Univ., West Germany
    Research Report 35
    Research Report 35
    October 1978
    98 p.

  • Dols, W. S.; Persily, A. K.
    view article (1.0)

    Study of Ventilation Measurement in an Office Building.
    National Institute of Standards and Technology, Gaithersburg, MD
    NISTIR 4905
    Bonneville Power Admin., Portland, OR, NISTIR 4905
    October 1992
    42 p.
    American Society for Testing and Materials. Airflow Performance of Building Envelopes, Components, and Systems. ASTM STP 1255. 1995, ASTM, West Conshocken, PA, Philadelphia, PA, Modera, M. P.; Persily, A. K., Editors, 23-46 p., ['1992', '1995']

  • Tan, Q.; Jaluria, Y.
    view article (1.0)

    Flow Through a Horizontal Vent in an Enclosure Fire.
    Rutgers, State University of New Jersey, New Brunswick
    National Institute of Standards and Technology, Gaithersburg, MD,
    American Society of Mechanical Engineers (ASME). Heat Transfer in Fire and Combustion Systems. HTD-Vol. 199. 1992, Am. Soc. of Mechanical Engineers, New York, NY, 115-122 p., 1992

  • Zhou, L.; Fernandez-Pello, A. C.
    view article (1.0)

    Turbulent, Concurrent, Ceiling Flame Spread: The Effect of Buoyancy.
    California Univ., Berkeley
    Combustion and Flame, Vol. 92, No. 1-2, 45-59, 1993
    National Institute of Standards and Technology, Gaithersburg, MD,

  • Ghosh, B. K.
    view article (1.0)

    Some Effects of Cross Wind on Ventilators.
    Fire Research Station, Borehamwood, England
    European Workshop on the Wind Effects on and the Aerodynamics of Natural Smoke and Heat Ventilators. January 29, 1992, Luxembourg, 23-37 p., 1992

  • Babrauskas, V.
    view article (1.0)

    Cone Calorimeter.
    National Institute of Standards and Technology, Gaithersburg, MD
    Chapter 4
    Chapter 4
    Heat Release in Fires, Elsevier Applied Science, NY, Babrauskas, V.; Grayson, S. J., Editors, 61-91 p., 1992