Gross, D.
view article (9.081846)
Estimating Air Leakage Through Doors for Smoke Control.
National Institute of Standards and Technology, Gaithersburg, MD
Fire Technology, Vol. 26, No. 1, 75-81, February 1990 <b>AND</b> Fire Safety Journal, Vol. 17, No. 2, 171-177, 1991,
1991
Lund University. Science of Building Fire Safety. Symposium to Honor Professor Ove Pettersson on His Retirement. May 2-4, 1989,
Lund, Sweden,
1-3 p.,
['1989', '1990', '1991']
Galbreath, M.
view article (9.081846)
Fire Tests of Wood Door Assemblies.
National Research Council of Canada, Ottawa, Ontario
NRCC 14678; Fire Study 36,
May 1975,
112 p.
Hedge, J. C.; Waterman, T. E.
view article (9.081846)
Fire Test Ratings for Shelter Components. Final Technical Report. October 15, 1967-May 15, 1969.
IIT Research Inst., Chicago, IL
Office of Civil Defense, Washington, DC,
IITRI project J6132; OCD Work Unit 1132A,
May 15, 1969,
63 p.
Marshall, S.
view article (9.081846)
In the Frame.
Fire Engineers Journal, Vol. 66, No. 264 / Fire Prevention, No. 400,
42-43,
January 2006
Cooper, L. Y.
view article (8.905932)
Need and Availability of Test Methods for Measuring the Smoke Leakage Characteristics of Door Assemblies.
National Bureau of Standards, Gaithersburg, MD
NBSIR 84-2876; ASTM STP 882,
May 1984,
34 p.
American Society for Testing and Materials. Fire Safety: Science and Engineering. ASTM STP 882. June 26-27, 1984,
Denver, CO,
Harmathy, T. Z., Editors,
310-329 p.,
1984
Cooper, L. Y.
view article (8.905932)
Measurement of the Smoke Leakage of Door Assemblies During Standard Fire Exposures. Final Report.
National Bureau of Standards, Gaithersburg, MD
Department of Labor, Washington, DC,
NBSIR 80-2004,
June 1980,
70 p.
Underwriters Laboratories, Incorporated
view article (8.905932)
Fire Tests of Door Assemblies. Standard for Safety. 8th Edition.
Underwriters Labs., Inc., Northbrook, IL
UL 10B,
July 26, 1993,
16 p.
Ruikar, V. G.
view article (8.905932)
Customized Tests for Detention and correctional Facilities.
Warnock Hersey Inc., Pittsburg, CA
ASTM Standardization News,
Vol. 24,
No. 5,
16-19,
May 1996
Gandhi, P. D.; Gruszynski, H. J.; Walther, R. L.
view article (8.905932)
National Fire Door Fire Test Project. Induced Failure Mode Test. Technical Report.
Underwriters Laboratories, Inc., Northbrook, IL
National Fire Protection Research Foundation, Quincy, MA,
Technical Report,
October 1995,
43 p.
Berhinig, R. M.
view article (8.74085)
Measurement of Air Flow Around Doors Under Standardizd Fire Test Conditions. June 1978-January 1979.
Underwriters Labs., Inc., Northbrook, IL
National Bureau of Standards, Gaithersburg, MD,
NBS GCR 81-330,
July 1981,
40 p.