FireDOC Search

displaying 31 - 40 results in total 115

  • Hakkarainen, T.
    view article (7.6411195)

    Post-Flashover Fires in Light and Heavy Timber Construction Compartments.
    VTT-Technical Research Center of Finland, Espoo
    Journal of Fire Sciences, Vol. 20, No. 2, 133-175, March 2002

  • Thomas, G.
    view article (7.6411195)

    Thermal Properties of Gypsum Plasterboard at High Temperatures.
    Victoria University of Wellington, Wellington, New Zealand
    Fire and Materials, Vol. 26, No. 1, 37-45, January/February 2002

  • Underwriters Laboratories, Incorporated
    view article (7.6411195)

    Structural Wood Members in a Floor-Ceiling Assembly.
    Underwriters Laboratories, Inc., Northbrook, IL
    File R5492-2; Project 81NK9398, October 6, 1981, 49 p.

  • Feng, M.; Wang, Y. C.
    view article (7.6411195)

    Experimental Study of Loaded Full-Scale Cold-Formed Thin-Walled Steel Structural Panels Under Fire Conditions.
    UMIST and University of Manchester, P.O. Box 88, Manchester M60 1QD, UK
    Fire Safety Journal, Vol. 40, No. 1, 43-63, February 2005

  • Bentz, D. P.; Prasad, K. R.; Yang, J. C.
    view article (7.6411195)

    Towards a Methodology for the Characterization of Fire Resistive Materials With Respect to Thermal Performance Models.
    National Institute of Standards and Technology, Gaithersburg, MD
    Fire and Materials, Vol. 30, No. 4, 311-321, July/August 2006

  • Grosshandler, W. L.; Manzello, S. L.; Maranghides, A.; Mizukami, T.
    view article (7.6411195)

    Analysis of Inter-Laboratory Testing of Non-Loadbearing Gypsum/Steel-Stud Wall Assemblies.
    National Institute of Standards and Technology, Gaithersburg, MD
    NISTIR 7471, December 2007, 37 p.

  • Schreuder, H.
    view article (7.6411195)

    Passive Fire Protection: Fire Rated Insulation.
    Rockwool
    International Fire Protection (IFP) Magazine, No. 36, 82-84, November 2008

  • Manzello, S. L.; Grosshandler, W. L.; Mizukami, T.
    view article (7.6411195)

    Furnace Testing of Full-Scale Gypsum Steel Stud Non-Load Bearing Wall Assemblies: Results of Multi-Laboratory Testing in Canada, Japan, and USA.
    National Institute of Standards and Technology, Gaithersburg, MD; Center for Better Living (CBL), Tsukuba, Ibaraki, Japan
    Fire Technology, Vol. 46, No. 1, 183-200, January 2010

  • Gypsum Association
    view article (7.55579)

    Fire Resistance. Design Manual. 10th Edition.
    Gypsum Association, Evanston, IL
    10th Edition, April 1983, 60 p.

  • Lee, B. T.
    view article (7.55579)

    Standard Room Fire Test Development at the National Bureau of Standards.
    National Bureau of Standards, Gaithersburg, MD
    ASTM STP 882,
    American Society for Testing and Materials. Fire Safety: Science and Engineering. ASTM STP 882. June 26-17, 1984, Denver, CO, Harmathy, T. Z., Editors, 29-44 p., 1984